Affiliation:
1. University of Nottingham, Nottingham, UK
Abstract
Factors determining the success or failure of combustion initiation using a glow plug have been investigated through experimental work on a single cylinder, common rail diesel engine with a geometric compression ratio of 15.5, and a quiescent combustion bomb with optical access. A glow plug was required to avoid engine misfires when bulk gas temperature at the start of injection was less than 413 °C. The distance between the glow plug and the spray edge, the glow plug temperature, and the bulk gas temperature were important factors in meeting two requirements for successful ignition: a minimum local temperature of 413 °C and a minimum air/fuel vapour equivalence ratio of 0.15–0.35.
Subject
Mechanical Engineering,Ocean Engineering,Aerospace Engineering,Automotive Engineering
Cited by
14 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献