Use of relative 12C/14C isotope ratios to estimate metabolite concentrations in the absence of authentic standards

Author:

Cuyckens Filip,Pauwels Nadine1,Koppen Valerie1,Leclercq Laurent1

Affiliation:

1. Drug Safety Sciences, Janssen R&D, Turnhoutseweg 30, 2340 Beerse, Belgium

Abstract

Background: There is considerable interest in the determination of relative abundances of human metabolites in plasma (and potentially excreta) with reasonable accuracy early on in the drug development process in order to make scientifically sound decisions with regard to the presence of potentially active or toxic disproportionate metabolites. At this point, authentic metabolite standards are generally not available. Results: A new methodology is proposed for the estimation of metabolite concentrations in the absence of authentic standards. A reference sample containing radiolabeled metabolites of interest is produced by incubating the 14C-labeled drug in vitro, and mixed with a sample to be quantitated containing the unlabeled metabolites. The 12C/14C isotope ratio is measured with high-resolution ESI–MS for each metabolite, and used as a basis for quantitation of the cold metabolite based on the concentration of radioactive metabolite, determined from independent analysis of the radioactive sample with LC-radiochemical detection. The 14C-labeled metabolite serves as an isotopically labeled internal standard, which corrects for any variations in injection volume, sample preparation, MS intensity drift, matrix effects and/or saturation of electrospray ionization. The approach was validated by the analysis of solutions containing variable amounts of the analyte with a fixed amount of radioactive standard on a QToF Synapt® G2 MS system. The same methodology was also successfully applied to first-in-human plasma samples analyzed on a LTQ-Orbitrap®. Conclusion: The metabolite abundances obtained by 12C/14C isotope ratio measurements showed suitable accuracy and precision and were very close to those obtained with matrix mixing. The parent drug concentrations also corresponded well with the bioanalytical results obtained with a validated LC–MS/MS method.

Publisher

Future Science Ltd

Subject

Medical Laboratory Technology,Clinical Biochemistry,General Pharmacology, Toxicology and Pharmaceutics,General Medicine,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3