Shul R. J.,Ashby C. I. H.,Willison C. G.,Zhang L.,Han J.,Bridges M. M.,Pearton S. J.,Lee J. W.,Lester L. F.
Abstract
ABSTRACTGaN etching can be affected by a wide variety of parameters including plasma chemistry and plasma density. Chlorine-based plasmas have been the most widely used plasma chemistries to etch GaN due to the high volatility of the GaClx and NClx etch products. The source of Cl and the addition of secondary gases can dramatically influence the etch characteristics primarily due to their effect on the concentration of reactive Cl generated in the plasma. In addition, high-density plasma etch systems have yielded high quality etching of GaN due to plasma densities which are 2 to 4 orders of magnitude higher than reactive ion etch (RIE) plasma systems. The high plasma densities enhance the bond breaking efficiency of the GaN, the formation of volatile etch products, and the sputter desorption of the etch products from the surface. In this study, we report GaN etch results for a high-density inductively coupled plasma (ICP) as a function of BCl3:Cl2 flow ratio, dc-bias, chamber pressure, and ICP source power. GaN etch rates ranging from ∼100 Å/min to > 8000 Å/min were obtained with smooth etch morphology and anisotropic profiles.
Publisher
Springer Science and Business Media LLC
Cited by
11 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献