The high-frequency response correction of eddy covariance fluxes – Part 1: An experimental approach and its interdependence with the time-lag estimation
-
Published:2021-07-28
Issue:7
Volume:14
Page:5071-5088
-
ISSN:1867-8548
-
Container-title:Atmospheric Measurement Techniques
-
language:en
-
Short-container-title:Atmos. Meas. Tech.
Author:
Peltola OlliORCID, Aslan Toprak, Ibrom AndreasORCID, Nemitz EikoORCID, Rannik Üllar, Mammarella IvanORCID
Abstract
Abstract. The eddy covariance (EC) technique has emerged as the prevailing method to observe the ecosystem–atmosphere exchange of gases, heat and momentum. EC
measurements require rigorous data processing to derive the fluxes that can be used to analyse exchange processes at the ecosystem–atmosphere
interface. Here we show that two common post-processing steps (time-lag estimation via cross-covariance maximisation and correction for limited
frequency response of the EC measurement system) are interrelated, and this should be accounted for when processing EC gas flux data. These findings
are applicable to EC systems employing closed- or enclosed-path gas analysers which can be approximated to be linear first-order sensors. These EC
measurement systems act as low-pass filters on the time series of the scalar χ (e.g. CO2, H2O), and this induces a time lag
(tlpf) between vertical wind speed (w) and scalar χ time series which is additional to the travel time of the gas signal in the
sampling line (tube, filters). Time-lag estimation via cross-covariance maximisation inadvertently accounts also for tlpf and hence
overestimates the travel time in the sampling line. This results in a phase shift between the time series of w and χ, which distorts the
measured cospectra between w and χ and hence has an effect on the correction for the dampening of the EC flux signal at high frequencies. This
distortion can be described with a transfer function related to the phase shift (Hp) which is typically neglected when processing EC
flux data. Based on analyses using EC data from two contrasting measurement sites, we show that the low-pass-filtering-induced time lag increases
approximately linearly with the time constant of the low-pass filter, and hence the importance of Hp in describing the high-frequency
flux loss increases as well. Incomplete description of these processes in EC data processing algorithms results in flux biases of up to 10 %, with
the largest biases observed for short towers due to the prevalence of small-scale turbulence. Based on these findings, it is suggested that spectral
correction methods implemented in EC data processing algorithms are revised to account for the influence of low-pass-filtering-induced time lag.
Funder
Academy of Finland Väisälän Rahasto European Commission Natural Environment Research Council
Publisher
Copernicus GmbH
Subject
Atmospheric Science
Reference46 articles.
1. Aslan, T., Peltola, O., Ibrom, A., Nemitz, E., Rannik, Ü., and Mammarella, I.: The high-frequency response correction of eddy covariance fluxes – Part 2: An experimental approach for analysing noisy measurements of small fluxes, Atmos. Meas. Tech., 14, 5089–5106, https://doi.org/10.5194/amt-14-5089-2021, 2021. a, b, c, d, e 2. Aubinet, M., Grelle, A., Ibrom, A., Rannik, U., Moncrieff, J., Foken, T., Kowalski, A. S., Martin, P. H., Berbigier, P., Bernhofer, C., Clement, R., Elbers, J., Granier, A., Grunwald, T., Morgenstern, K., Pilegaard, K., Rebmann, C., Snijders, W., Valentini, R., and Vesala, T.:
Estimates of the annual net carbon and water exchange of forests: The EUROFLUX methodology,
Adv. Ecol. Res.,
30, 113–175, 2000. a, b, c 3. Aubinet, M., Vesala, T., and Papale, D.: Eddy covariance: a practical guide to measurement and data analysis, Springer Atmospheric Sciences, Springer, Dordrecht, 2012. a, b, c 4. Aubinet, M., Joly, L., Loustau, D., De Ligne, A., Chopin, H., Cousin, J., Chauvin, N., Decarpenterie, T., and Gross, P.: Dimensioning IRGA gas sampling systems: laboratory and field experiments, Atmos. Meas. Tech., 9, 1361–1367, https://doi.org/10.5194/amt-9-1361-2016, 2016. a, b 5. Baldocchi, D. D.:
Assessing the eddy covariance technique for evaluating carbon dioxide exchange rates of ecosystems: past, present and future,
Glob. Change Biol.,
9, 479–492, https://doi.org/10.1046/j.1365-2486.2003.00629.x, 2003. a
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|