Evaluating near Infrared Techniques for Quantitative Analysis of Carbohydrates in Fruit Juice Model Systems

Author:

Segtnan V.H.1,Isaksson T.1

Affiliation:

1. Department of Food Science, Agricultural University of Norway, PO Box. 5036, N-1432 Ås, Norway

Abstract

Several techniques for measuring quality parameters in foods by the use of near infrared (NIR) technology have been reported. The aim of this experiment is to evaluate the main techniques in order to find the optimal measurement conditions for NIR analysis of carbohydrates in fluid food systems. Two different model systems were studied, each system containing 61 designed samples. The first system was designed to give scatter, and was based on a commercial orange juice. The other system was designed to be scatter-free, and was based on distilled water. To all samples were added the same total amounts of glucose, fructose and sucrose, and measured using the following NIR techniques: transmittance measurements in cuvettes, dry extract diffuse reflectance (DESIR), fibre-optic transflectance and fibre-optic transmittance. Calibration models were made by partial least squares regression in the spectral regions 780–2500nm for DESIR measurements, 1100–1315nm for 10mm pathlengths and 1100–1880+2130–2350nm for 1mm pathlengths. The models were fully cross-validated. Optimal prediction errors (Root Mean Square Error of Prediction, Cross-Validated) for DESIR measurements ranged from 0.020 to 0.030% (w/w), while 1mm cuvette values ranged from 0.008 to 0.012%. For these techniques there were only small differences between juice and water samples. Using fibre-optics, 1mm transmittance gave values in the range 0.068–0.081% for juice samples and 0.022–0.066% for water samples, while 1mm transflectance gave 0.044–0.051% for juice samples and 0.045–0.078% for water samples. 10mm pathlengths provided substantially higher prediction errors than 1mm for all techniques investigated. From these results, two main conclusions can be drawn. First, when measuring off-line, direct transmittance measurements in cuvettes gave better prediction results than DESIR. Second, when using fibre-optics, transflectance gave lower prediction errors than transmittance for scattering samples, while transmittance performed better than transflectance for non-scattering samples.

Publisher

SAGE Publications

Subject

Spectroscopy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3