Rapid MIC testing with the sensititre autoreader

Author:

Staneck J L1,Allen S D1,Harris E E1,Tilton R C1

Affiliation:

1. Department of Pathology and Laboratory Medicine, University of Cincinnati College of Medicine, Ohio 45267-0714.

Abstract

Automated microdilution MIC results, obtained with the Autoreader (Sensititre, Inc., Salem, N.H.) following 5 h of incubation, were compared with manually read, concurrent control MICs following 18 h of incubation in a three-laboratory comparative study. A total of 704 members of the family Enterobacteriaceae or similar gram-negative organisms were tested against 17 antimicrobial agents. Autoreader MICs were within 1 doubling dilution of control values in 92.9% of instances. Discrepancies of +/- 2 doubling dilutions and +/- 3 or greater doubling dilutions were noted in 4.5 and 2.6%, respectively, of the 7,687 drug-organism combinations analyzed. The majority of errors occurred when beta-lactam antimicrobial agents were tested with a variety of different species. MICs at 5 h, when Pseudomonas aeruginosa was used, were possible in only half the isolates tested and yielded data on only a limited number of drugs in the remaining instances. Excluding results obtained with penicillin and ampicillin, which were uniformly poor, Staphylococcus aureus Autoreader values were within +/- 1 doubling dilution of control values in 93.6% of instances, 5.4% varied by +/- 2 dilutions, and only 1% of test values by +/- 3 or more dilutions from control values for 82 isolates tested against nine antimicrobial agents. Of eight additional S. aureus isolates tested that were resistant to methicillin, only one was read correctly by the Autoreader, with results on the remaining seven appearing as either insufficient growth or as total resistance to all drugs tested. Interlaboratory reproducibility was excellent for selected isolates of S. aureus and gram-negative bacilli. The accuracy of the Sensititre Autoreader MIC results was comparable to that of other same-day quantitative systems for members of the family Enterobacteriaceae and S. aureus, while the economic and procedural advantages of the broth microdilution method was maintained.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3