Reliability of the MS-2 system in detecting methicillin-resistant Staphylococcus aureus

Author:

Boyce J M,White R L,Bonner M C,Lockwood W R

Abstract

The MS-2 system (Abbott Diagnostics, Division of Abbott Laboratories, Dallas, Tex.) is an automated system capable of rapid antimicrobial susceptibility testing. However, the short incubation periods used by the device may adversely affect its ability to detect slowly growing resistant organisms. Shortly after the introduction of the MS-2 system into the University of Mississippi Medical Center clinical microbiology laboratory, we noted discrepancies between the MS-2 and the disk diffusion susceptibility reports when methicillin-resistant Staphylococcus aureus isolates were tested. Subsequently, we determined the susceptibilities of 75 such isolates by the MS-2 and Kirby-Bauer disk diffusion methods and measured the minimum inhibitory concentrations of methicillin, oxacillin, and cephalothin for 33 of the 75 isolates by standardized agar dilution techniques. There was only 47% overall agreement between the MS-2 and disk diffusion methods when methicillin was tested and 15% agreement when cephalothin was the test drug. There was 93% or more overall agreement between the two methods when other antimicrobial agents were tested. The minimum inhibitory concentration of methicillin was greater than or equal to 16 micrograms/ml for all 33 isolates evaluated by the agar dilution method. A comparison of the MS-2 and agar dilution results revealed an overall agreement of 49% when the susceptibilities to methicillin were determined. The MS-2 system reported that multiple methicillin-resistant S. aureus isolates obtained from a single patient were either resistant, intermediate, or sensitive to methicillin. Inconsistent results were also obtained when a single isolate was tested simultaneously in 10 cuvette cartridges. We conclude that the MS-2 system does not reliably detect methicillin and cephalothin resistance among S. aureus.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference17 articles.

1. Clinical evaluation of automated antibiotic susceptibility testing with the MS-2 system;Barnes W. G.;J. Clin. Microbiol.,1980

2. Infections and antibiotic use among patients at Boston City Hospital;Barrett F. F.;N. Engl. J. Med.,1968

3. Reliability of the microdilution technic for detection of methicillin-resistant strains of Staphylococcus aureus;Barry A. L.;Am. J. Clin. Pathol.,1977

4. Barry A. L. and C. Thornsberry. 1980. Susceptibility testing: diffusion test procedures p. 463-474. In E. H. Lennette A. Balows W. J. Hausler Jr. and J. P. Truant (ed.) Manual of clinical microbiology 3rd ed. American Society for Microbiology Washington D.C.

5. Frequency and some properties of clinical isolates of methicillin-resistant Staphylococcus aureus;Blackwe D;Am. J. Clin. Pathol.,1975

Cited by 39 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3