Reliability, Validity, and Comparison of Barbell Velocity Measurement Devices during the Jump Shrug and Hang High Pull

Author:

Suchomel Timothy J.12,Techmanski Baylee S.3,Kissick Cameron R.4,Comfort Paul2ORCID

Affiliation:

1. Department of Human Movement Sciences, Carroll University, Waukesha, WI 53186, USA

2. Directorate of Sport, Exercise, and Physiotherapy, University of Salford, Salford M6 6PU, UK

3. Athlete Performance, Mequon, WI 53092, USA

4. New York Mets, Queens, NY 11368, USA

Abstract

This study examined the reliability, potential bias, and practical differences between the GymAware Powertool (GA), Tendo Power Analyzer (TENDO), and Push Band 2.0 (PUSH) during the jump shrug (JS) and hang high pull (HHP) performed across a spectrum of loads. Fifteen resistance-trained men performed JS and HHP repetitions with 20, 40, 60, 80, and 100% of their 1RM hang power clean, and mean (MBV) and peak barbell velocity (PBV) were determined by each velocity measurement device. Least-products regression and Bland–Altman plots were used to examine instances of proportional, fixed, and systematic bias between the TENDO and PUSH compared to the GA. Hedge’s g effect sizes were also calculated to determine any meaningful differences between devices. The GA and TENDO displayed excellent reliability and acceptable variability during the JS and HHP while the PUSH showed instances of poor–moderate reliability and unacceptable variability at various loads. While the TENDO and PUSH showed instances of various bias, the TENDO device demonstrated greater validity when compared to the GA. Trivial–small differences were shown between the GA and TENDO during the JS and HHP exercises while trivial–moderate differences existed between GA and PUSH during the JS. However, despite trivial–small effects between the GA and PUSH devices at 20 and 40% 1RM during the HHP, practically meaningful differences existed at 60, 80, and 100%, indicating that the PUSH velocity outputs were not accurate. The TENDO appears to be more reliable and valid than the PUSH when measuring MBV and PBV during the JS and HHP.

Publisher

MDPI AG

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,Histology,Rheumatology,Anatomy

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3