Method for validating CT length measurement of cracks inside solder joints

Author:

Garami Tamás,Krammer Oliver,Harsányi Gábor,Martinek Péter

Abstract

Purpose – This paper aims to develop a method to measure the length of cracks inside solder joints, which enables the validation of computed tomography (CT) crack length measurements. Design/methodology/approach – Cracks were formed inside solder joints intentionally by aging solder joints of 0603 size resistors with thermal shock (TS) test (−40 to +140°C, 2,000 cycles), and CT images were captured about them with different rotational increment (1/4, 1/2 and 1°) of sample projection. The length of cracks was also measured with our method, which is based on capturing high-resolution radiography X-ray images about the cracks in two perpendicular projection planes. The radiography results were compared to the CT measurements. The percentage error for the different CT rotational increment settings was calculated, and the optimal CT settings have been determined. Findings – The results have proven that reducing the rotational increment increases the sharpness of the captured images and the accuracy of crack length measurements. Nevertheless, the accuracy compared to high-resolution radiography measurements is only slightly better at 1/4° rotational increment than in the case of 1/2° rotational increment. It should be also noted that the 1/4° increment requires twice as much time for capturing the images as the 1/2° increment. So, the 1/2° rotational increment of sample projection is the optimal setting in our investigated case for measuring crack lengths. Practical implications – The developed method is applicable to find the optimal settings for CT crack length measurements, which provides faster analysation of large quantity samples used, e.g. at life-time tests. Originality/value – There is a lack of information in the literature regarding the optimisation of CT measurement set-up, e.g. a slightly larger value of the sample rotational increment can provide acceptable resolution with much faster processing time. Thus, the authors developed a method and performed research about optimising CT measurement parameters.

Publisher

Emerald

Subject

Electrical and Electronic Engineering,Condensed Matter Physics,General Materials Science,Electrical and Electronic Engineering,Condensed Matter Physics,General Materials Science

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3