Comparison of Stable Isotopes and Radioisotopes in the Measurement of Iron Absorption in Healthy Women

Author:

Barrett Jon F. R.1,Whittaker Paul G1,Fenwick John D.2,Williams John G.3,Lind Tom1

Affiliation:

1. *University Department of Obstetrics and Gynaecology, Royal Victoria Infirmary, Newcastle-upon-Tyne, U.K.

2. Department of Medical Physics, Newcastle General Hospital, Newcastle-upon-Tyne, U.K.

3. NERC ICP-MS Facility, Imperial College at Silwood Park, Ascot, Berkshire, U.K.

Abstract

1. Stable isotope methods are being used to investigate the absorption of dietary iron. In order to be certain that this new methodology is accurate, we have compared results obtained using stable isotopes and inductively coupled plasma mass spectrometry with those determined using a radioisotope and whole body counting. 2. The stable isotope 54Fe (2.8 mg) was given to 10 healthy non-pregnant women. Six women received the isotope in aqueous form, and four took it with a meat meal. The 54Fe served as a carrier for 10 ng of the radioisotope 59Fe. An ampoule (200 μg) of the isotope 57Fe or 58Fe was then given intravenously, and in serum samples taken over the next 10 h the ratios of the stable iron isotopes were measured by inductively coupled plasma mass spectrometry and the oral iron absorption was calculated. This was then compared with the results obtained by using a whole body counter to measure (on day 0 and day 14) the γ-activity emitted by the radioisotope. 3. The mean iron absorption measured by both methods ranged from 8% to 45%. Measurement of the post-absorptive serum enrichment of the stable isotopes provided estimates of absorption from both aqueous and food iron which were similar to that yielded by whole body counting, the mean difference being −1.5% (95% confidence interval −5.2 to 2.1%). Absorption estimated by stable isotopes exhibited the same inverse relationship with the serum ferritin level (body iron stores) to that known to exist with whole body counting. Similar estimates of food iron absorption were obtained irrespective of the type of isotope used as an extrinsic label, implying that stable isotopes are as valid as radioisotopes in reflecting intrinsic food iron absorption. 4. This study validates the use of stable isotopes and post-absorption curves as a new and accurate technique in the measurement of iron absorption.

Publisher

Portland Press Ltd.

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3