In this paper, a multizone model is developed to investigate the performance of an economizer under all conditions. The model primarily determines the economizer’s distribution parameters under all conditions with a small computational cost. Both the steady-state and dynamic behavior are calculated. These results are shown to be accurate and reliable using a computational fluid dynamic (CFD) model and the operational data obtained from a 600 MW boiler unit in Hubei province, China. Additionally, the model is used to predict the distribution characteristics during some fault conditions.
Subject
Geochemistry and Petrology,Mechanical Engineering,Energy Engineering and Power Technology,Fuel Technology,Renewable Energy, Sustainability and the Environment