Patient-Specific Compliant Vessel Manufacturing Using Dip-Spin Coating of Rapid Prototyped Molds

Author:

Arcaute Karina1,Wicker Ryan B.1

Affiliation:

1. W.M. Keck Center for 3D Innovation, College of Engineering, University of Texas at El Paso, El Paso, TX 79968

Abstract

A procedure for manufacturing cardiovascular system models using patient-specific data, rapid prototyping, and a multistep dip-spin coating process is presented here. Improvements to a previously developed process permitted the fabrication of flexible complex vascular replicas. The primary improvement included the development of a two-axis rotation mechanism that enabled a pseudorandom rotation of the coated mold in space, providing uniform coats. Other improvements included the use of a low viscosity (1500–2000cP) silicone solution that allowed for complete coverage of the mold, and developing a procedure for fixing defects. The dip-spin coating procedure was shown to be effective for the manufacture of compliant cardiovascular membranes, such as an arterial bypass graft with an internal flow passage and an abdominal aorta with nonuniform radial geometry, tapered diameters, bifurcations, and small branches. Results from a design of experiments comparing two dipping setups demonstrated that horizontally dipping the model produced coatings with more uniform thicknesses along the length of the model when compared to vertical dipping. For a 250-mm-long model, the difference in thickness between the top and bottom of the membrane was 0.42±0.069mm and 0.09±0.077mm for vertical and horizontal dippings, respectively. Mold diameter also affected the thickness of the membrane, with membrane thickness increasing as mold diameter decreased. Thickness data comparing locations at approximately the same height of the mold but with different diameters showed thicknesses of 2.54±0.198mm and 1.95±0.140mm for 7.85mm and 15.20mm diameters, respectively. Moreover, the differences in thickness between these locations were 0.60±0.128mm and 0.58±0.231mm for vertical and horizontal dippings, respectively; thus, membrane thickness variations occurred with mold diameter irrespective of the dipping setup. Depending on the prescribed tolerance for membrane thickness, the vertical dipping setup may be recommended for use because (1) it was easier to use since only the mold was immersed in the coating solution and no special protection of the dipping mechanism was required and (2) it produced fewer defects in the coatings since the solution always dripped from downfacing surfaces of the mold. Using this dip-spin coating procedure, patient-specific cardiovascular membranes can be manufactured and used in the development of medical devices, research requiring accurate anatomical models, and education and training.

Publisher

ASME International

Subject

Industrial and Manufacturing Engineering,Computer Science Applications,Mechanical Engineering,Control and Systems Engineering

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3