Requirements for Mesh Resolution in 3D Computational Hemodynamics
Author:
Prakash Sujata1, Ethier C. Ross2
Affiliation:
1. Department of Mechanical and Industrial Engineering 2. Department of Mechanical and Industrial Engineering, and Institute for Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada M 5S 3G8
Abstract
Computational techniques are widely used for studying large artery hemodynamics. Current trends favor analyzing flow in more anatomically realistic arteries. A significant obstacle to such analyses is generation of computational meshes that accurately resolve both the complex geometry and the physiologically relevant flow features. Here we examine, for a single arterial geometry, how velocity and wall shear stress patterns depend on mesh characteristics. A well-validated Navier-Stokes solver was used to simulate flow in an anatomically realistic human right coronary artery (RCA) using unstructured high-order tetrahedral finite element meshes. Velocities, wall shear stresses (WSS), and wall shear stress gradients were computed on a conventional “high-resolution” mesh series (60,000 to 160,000 velocity nodes) generated with a commercial meshing package. Similar calculations were then performed in a series of meshes generated through an adaptive mesh refinement (AMR) methodology. Mesh-independent velocity fields were not very difficult to obtain for both the conventional and adaptive mesh series. However, wall shear stress fields, and, in particular, wall shear stress gradient fields, were much more difficult to accurately resolve. The conventional (nonadaptive) mesh series did not show a consistent trend towards mesh-independence of WSS results. For the adaptive series, it required approximately 190,000 velocity nodes to reach an r.m.s. error in normalized WSS of less than 10 percent. Achieving mesh-independence in computed WSS fields requires a surprisingly large number of nodes, and is best approached through a systematic solution-adaptive mesh refinement technique. Calculations of WSS, and particularly WSS gradients, show appreciable errors even on meshes that appear to produce mesh-independent velocity fields.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference27 articles.
1. Moore, J. A., Steinman, D. A., Prakash, S., Johnston, K. W., and Ethier, C. R., 1999, “A Numerical Study of Blood Flow Patterns in Anatomically Realistic and Simplified End-to-Side Anastomoses,” J. Biomech. Eng., 121, pp. 265–272. 2. Taylor, C. A., Hughes, T. J. R., and Zarins, C. K., 1998, “Finite Element Modeling of Blood Flow in Arteries,” Comput. Methods Appl. Mech. Eng., 158, pp. 155–196. 3. Hofer, M., Rappitsch, G., Perktold, K., Trubel, W., and Schima, H., 1996, “Numerical Study of Wall Mechanics and Fluid Dynamics in End-to-Side Anastomoses and Correlation to Intimal Hyperplasia,” J. Biomech., 29, pp. 1297–1308. 4. Noori, N., Scherer, R., Perktold, K., Czerny, M., Karner, G., Trubel, M., Polterauer, P., and Schima, H., 1999, “Blood Flow in Distal End-to-Side Anastomoses With PTFE and a Venous Patch: Results of an In Vitro Flow Visualization Study,” Eur. J. Vasc. Endovasc Surg., 18, pp. 191–200. 5. Botnar, R., Rappitsch, G., Scheidegger, M. B., Liepsch, D., Perktold, K., and Boesiger, P., 2000, “Hemodynamics in the Carotid Artery Bifurcation: A Comparison Between Numerical Simulations and In Vitro MRI Measurements,” J. Biomech., 33, pp. 137–144.
Cited by
113 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|