A Numerical Study of Blood Flow Patterns in Anatomically Realistic and Simplified End-to-Side Anastomoses
Author:
Moore J. A.1, Steinman D. A.2, Prakash S.3, Johnston K. W.4, Ethier C. R.1
Affiliation:
1. Department of Mechanical Engineering; Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada 2. Imaging Research Lab, J. P. Robarts Research Institute, London, Ontario, Canada; Department of Medical Biophysics, University of Western Ontario, London, Ontario, Canada 3. Department of Mechanical Engineering, University of Toronto, Toronto, Ontario, Canada 4. Institute of Biomedical Engineering; Department of Surgery, University of Toronto, Toronto, Ontario, Canada
Abstract
Purpose: Recently, some numerical and experimental studies of blood flow in large arteries have attempted to accurately replicate in vivo arterial geometries, while others have utilized simplified models. The objective of this study was to determine how much an anatomically realistic geometry can be simplified without the loss of significant hemodynamic information. Method: A human femoral-popliteal bypass graft was used to reconstruct an anatomically faithful finite element model of an end-to-side anastomosis. Nonideal geometric features of the model were removed in sequential steps to produce a series of successively simplified models. Blood flow patterns were numerically computed for each geometry, and the flow and wall shear stress fields were analyzed to determine the significance of each level of geometric simplification. Results: The removal of small local surface features and out-of-plane curvature did not significantly change the flow and wall shear stress distributions in the end-to-side anastomosis. Local changes in arterial caliber played a more significant role, depending upon the location and extent of the change. The graft-to-host artery diameter ratio was found to be a strong determinant of wall shear stress patterns in regions that are typically associated with disease processes. Conclusions: For the specific case of an end-to-side anastomosis, simplified models provide sufficient information for comparing hemodynamics with qualitative or averaged disease locations, provided the “primary” geometric features are well replicated. The ratio of the graft-to-host artery diameter was shown to be the most important geometric feature. “Secondary” geometric features such as local arterial caliber changes, out-of-plane curvature, and small-scale surface topology are less important determinants of the wall shear stress patterns. However, if patient-specific disease information is available for the same arterial geometry, accurate replication of both primary and secondary geometric features is likely required.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference40 articles.
1. Bassiouny
H. S.
, WhiteS., GlagovS., ChoiE., GiddensD. P., and ZarinsC. K., “Anastomotic intimal hyperplasia: mechanical injury or flow induced?” J. Vasc. Surg., 15:708–717, 1992. 2. Binns
R. L.
, KuD. N., StewartM. T., AnsleyJ. P., and CoyleK. A., “Optimal graft diameter: effect of wall shear stress on vascular healing,” J. Vasc. Surg., 10(3): 326–337, 1989. 3. Butany
J. W.
, DavidT. E., and OjhaM., “Histological and morphometric analyses of early and late aortocoronary vein grafts and distal anastomoses,” Can. J. Cardiol., 14(5): 671–677, 1998. 4. Chandran
K. B.
, VoneshM. J., RoyA., GreenfieldS., KaneB., GreeneR., and McPhersonD. D., “Computation of vascular flow dynamics from intravascular ultrasound images,” Med. Eng. Phys., 18(4): 295–304, 1996. 5. Duncan
D. D.
, BargeronC. B., BorchardtS. E., DetersO. J., GearhartS. A., MarkF. F., and FriedmanM. H., “The effect of compliance on wall shear in casts of a human aortic bifurcation,” ASME JOURNAL OF BIOMECHANICAL ENGINEERING, 112: 183–188, 1990.
Cited by
81 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|