Author:
Zhu Guocheng,Zhang Shanshan,Bian Yongning,Hursthouse Andrew S
Abstract
In drinking water treatment, disinfection is a key step to ensure the safety of water quality and people's health but little is known of the relationship between chlorine consumption and water matrix properties from varied sources (BWM). In this study, we measured the fluorescence from fractions of NOM (FFN) for the relevant BWM. This included the evaluation of three components: the chlorine-dependence factor (CDF) (DOC and NH3-N), the BWM (such as NO3<sup>-</sup>, NO2<sup>-</sup> and turbidity), and FFN (I-V fluorescence fractions). Multi-linear regression model was used to fit the data. Results showed that when using the CDF, BWM and FNN, in the prediction of chlorine consumption showed the (R<sup>2</sup>) values were 0.72, 0.71 and 0.41, respectively. While the FNN did not fit the model well it did enhance the model using CDF by 11.26%. The FNN is not effective in enhancement of the BWM response to the model. Combination of the CDF, BWM and FNN or that of the CDF and BWM were both effective in prediction of chlorine consumption.
Funder
Natural Science Foundation of Hunan Province of China
China Postdoctoral Science Foundation
National Natural Science Foundation of China
Publisher
Korean Society of Environmental Engineering
Subject
Environmental Engineering
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献