Case history of liner veneer instability

Author:

Amaya P.1,Queen B.2,Stark T. D.3,Choi H.4

Affiliation:

1. Geotechnical Engineering Section, American Electric Power Service Corporation 1 Riverside Plaza Columbus, OH 43215-2373, USA Telephone: , Telefax: ,

2. South East District Office, Division of Solid and Infectious Waste Management Ohio EPA, 2195 Front Street, Logan, OH 43138, USA Telephone: , Telefax: ,

3. Department of Civil and Environmental Engineering, The University of Illinois 2217 NCEL, 205 N. Mathews Ave., Urbana, IL 61801-2352, USA Telephone: , Telefax: ,

4. Department of Civil and Environmental Engineering., Korea University Anam- Dong, Seongbuk-Gu, Seoul 136-713, South Korea Telephone: , Telefax: ,

Abstract

Construction conditions experienced during installation of a landfill geocomposite liner system led to two slides on a 3H:1V slope during construction. The landfill was being developed for final disposal of flue gas desulfurization by-product material (FGD). The slides occurred in two different areas of the 3H:1V slope and encompass 10,500 and 20,235 m2 in the Fall of 1996 and Summer of 1997, respectively. The slides developed by movement along the PVC geomembrane/compacted clay liner interface during or shortly after placement of the protective FGD cover material over the drainage sand layer. Laboratory direct shear tests revealed that the shear strength of this interface is sensitive to the moisture content of the exposed compacted clay liner. The direct shear tests revealed reductions in the available shear strength of 35% and 37% for the peak and large displacement values as the compacted clay liner moisture content increased by 8 percentage points. In addition, shear stresses induced by surface traffic activities might result in shear displacements along the interface, which in some cases were large enough to lower the available shear resistance of the geomembrane/compacted clay interface to a post-peak or large displacement value. This paper discusses the slides, direct shear testing, slope stability analyses used to evaluate the mobilized interface shear strength parameters, the relationship between moisture content and geomembrane/compacted clay liner interface strength, and the effect of shear displacement on the mobilized shear strength.

Publisher

Thomas Telford Ltd.

Subject

Geotechnical Engineering and Engineering Geology,Civil and Structural Engineering

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3