Are We Underestimating the Problem of Ultrafiltration in Peritoneal Dialysis Patients?

Author:

McCafferty Kieran1,Fan Stanley L.-S.1

Affiliation:

1. Department of Renal Medicine and Transplantation, Barts and The London Hospital NHS Trust, London, United Kingdom

Abstract

Background Accurate measurement of ultrafiltration (UF) is important to improve the morbidity and mortality of peritoneal dialysis (PD) patients. The introduction of “flush-before-fill” PD systems has led to improved peritonitis rates. Partly to compensate for dialysate lost during flush-before-fill, extra dialysate was added to each PD bag. A 2-L PD bag now contains a mean volume of 2.225 L. That overfill volume might be erroneously measured as UF. We previously studied how this confounding factor might be affecting the diagnosis of UF failure and found that almost all units were overestimating daily UF by 900 mL. We now repeat the study to determine if the accuracy of UF estimation has improved. Methods We conducted a telephone survey of PD units in the UK to determine how drain bags are weighed and how UF is calculated during formal assessment of adequacy and the peritoneal equilibrium test (PET). We also retrospectively analyzed our last 100, 24-hour dialysate collections and PET results to determine the potential clinical impact of overestimating UF. Results There has been an improvement since our last study, but 70% of PD units in the UK are still overestimating daily UF in patients on continuous ambulatory PD (CAPD). Half the surveyed units also inaccurately calculate UF during the PET, and 85% were reporting results of PET and 24-hour dialysate collections through the software provided by Baxter Healthcare. By including the overfill volume, 73% of patients with daily UF <750 mL would not be diagnosed as having inadequate daily UF (assuming that all were fluid overloaded and anuric). Similarly, 73% with potential UF failure during the PET (4-hour UF <100 mL) would be missed if overfill volume was misrepresented as UF. Conclusion For patients undergoing CAPD, there requires standardization on when drain bags are weighed. Awareness that calculation of UF must exclude overfill volumes has improved but remains poor. The PD Adequest software (Baxter Healthcare, Compton, UK) is widely adopted in the UK and perhaps it could draw attention of users to the potential of UF overestimation in CAPD patients.

Publisher

SAGE Publications

Subject

Nephrology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3