Fluid Status, Blood Pressure, and Cardiovascular Abnormalities in Patients on Peritoneal Dialysis

Author:

Konings Constantijn J.A.M.1,Kooman Jeroen P.1,Schonck Marc2,Dammers Ruben3,Cheriex Emiel4,Meulemans Andrea P. Palmans4,Hoeks Arnold P.G.3,Van Kreel Bernardus5,Gladziwa Ulrich6,van der Sande Frank M.1,Leunissen Karel M.L.1

Affiliation:

1. Department of Internal Medicine and Nephrology, Academic Hospital Maastricht

2. Department of Internal Medicine, West Fries Gasthuis Hoorn, Academic Hospital Maastricht, The Netherlands

3. Department of Biophysics, University of Maastricht, Academic Hospital Maastricht, The Netherlands

4. Department of Cardiology, Academic Hospital Maastricht, The Netherlands

5. Department of Clinical Chemistry, Academic Hospital Maastricht, The Netherlands

6. Kuratorium für Heimdialyse, Würselen, Germany

Abstract

♦ Objective Hypertension, reduced arterial distensibility, and left ventricular hypertrophy (LVH) are risk factors for mortality in hemodialysis patients. However, few studies have focused on the relation between fluid status, blood pressure (BP), and cardiovascular abnormalities in peritoneal dialysis (PD) patients. This study was designed, first, to assess, using tracer dilution techniques, fluid status in PD patients compared to a control population of stable renal transplant (RTx) patients; second, to study the relation between fluid status, BP, and arterial wall abnormalities; third, to assess the determinants of cardiac structure; and last, to compare office and ambulatory BP measurements with respect to cardiac abnormalities. ♦ Design Cross-sectional study. ♦ Setting Multicenter study. ♦ Patients 41 stable PD patients with a mean Kt/V urea of 2.4 ± 0.7, and 77 stable RTx patients. ♦ Intervention Fluid status was assessed by tracer dilution techniques: extracellular volume (ECV) with bromide dilution; total body water (TBW) with deuterium oxide; and plasma volume (PV) with dextran 70. Echocardiography was performed to assess left ventricular mass (LVM), left ventricular end diastolic diameter (LVEDD), and relative wall thickness as indicators of LVH. Echography of the common carotid artery was performed to assess arterial distensibility. Both office and 24-hour ambulatory BP measurements were performed. ♦ Results Fluid status, as assessed by ECV corrected for body surface area (BSA) (ECV:BSA), was significantly different between PD and RTx patients (9.4 ± 2.6 vs 8.6 ± 1.2 L/m2, p < 0.05). In 36.6% of the PD patients, ECV:BSA was above the 90th percentile of the RTx patients. Fluid status corrected for BSA, assessed by TBW (TBW:BSA), ECV (ECV:BSA), or plasma volume (PV:BSA), was significantly related to diastolic BP (DBP) ( r = 0.35, r = 0.37, r = 0.53; p < 0.05). Arterial distensibility of the common carotid artery was related to systolic BP (SBP) ( r = –0.36, p < 0.05). ECV was significantly related to LVEDD ( r = 0.41, p < 0.05) as a marker of eccentric LVH, whereas arterial distensibility was related to relative wall thickness ( r = –0.53, p < 0.001) as a marker of concentric LVH. An abnormal day–night BP rhythm, which was not related to fluid status, was observed in 68.4% of patients. Ambulatory DBP and SBP but not office DBP and SBP were related to LVM ( r = 0.43, r = 0.46; p < 0.01). ♦ Conclusions A large proportion of PD patients whose treatment prescriptions are in accordance with the Dialysis Outcomes Quality Initiative guidelines were found to be overhydrated compared with a population of stable RTx patients. Fluid status was significantly related to DBP and eccentric LVH, whereas arterial distensibility of the common carotid artery was significantly related to SBP and concentric LVH. In contrast to ambulatory BP, office BP was not related to LVM.

Publisher

SAGE Publications

Subject

Nephrology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3