Differences in predicting glucose absorption from peritoneal dialysate compared to measured absorption in peritoneal dialysis patients treated by continuous ambulatory peritoneal dialysis and ambulatory peritoneal dialysis cyclers

Author:

Tangwonglert Theerasak1,Davenport Andrew2ORCID

Affiliation:

1. Nephrology Division, Department of Medicine, Phramongkutklao Hospital, Bangkok, Thailand

2. UCL Department of Nephrology, Royal Free Hospital, University College London, London, UK

Abstract

Background and aims: Glucose-containing peritoneal dialysates are used to generate an osmotic gradient for the convective removal of water and sodium. Predictive equations were developed to estimate glucose absorption without having to formally measure changes in dialysate glucose. In view of the changes in peritoneal dialysis prescriptions over time, we compared predicted and measured glucose absorption. Subjects/methods: We measured peritoneal glucose losses when peritoneal dialysis patients attended their first assessment of peritoneal membrane function, and compared this to glucose exposure and Kidney Disease Outcomes Quality Initiative, Grodstein and Bodnar predictive equations. Results: We studied 689 patients; 329 (56.9%) males, 53 (37.1%) diabetics, with mean age 57.1 ± 16.2 years, with 186 treated by automated peritoneal dialysis cyclers and 377 by automated peritoneal dialysis with a daytime icodextrin exchange and 126 by continuous ambulatory peritoneal dialysis. Using Bland -Altman analysis, all equations demonstrated systematic bias overestimating glucose absorption with increasing glucose absorption. For continuous ambulatory peritoneal dialysis patients, the Kidney Disease Outcomes Quality Initiative formula underestimated glucose absorption (bias 188 (−39 to 437) mmol/day, as did Grodstein (bias 37.9 (−105 to 29) mmol/day, whereas mean bias for Bodnar was −29 (−130 to 180)). There was systematic overestimation for all equations for both automated peritoneal dialysis with and without a daytime exchange, with increasing bias with greater glucose absorption. Conclusion: Although formally measuring peritoneal glucose absorption is time consuming and requires patient co-operation, current predictive equations overestimate glucose absorption and do not provide accurate estimations of glucose absorption particularly for automated peritoneal dialysis patients.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3