Angiographic and clinical outcomes from 396 aneurysms treated with the pipeline flex embolization device with shield technology

Author:

Lylyk Ivan1ORCID,Scrivano Esteban1ORCID,Lundquist Javier1,Bleise Carlos1ORCID,Perez Nicolas1,Lylyk Pedro Nicolas1,Nella-Castro Rodolfo1,Lylyk Pedro1

Affiliation:

1. Department of Interventional Neuroradiology and Neurosurgery, Instituto Médico ENERI, Clínica La Sagrada Familia, Jose Hernandez, Buenos Aires, Argentina

Abstract

Background The PEDESTRIAN registry demonstrated high rates of complete long-term occlusion and good clinical outcomes among patients with intracranial aneurysms treated with the pipeline embolization device. The pipeline flex embolization device with shield technology was introduced to minimize thromboembolic complications. In this study, we investigated the safety and effectiveness of pipeline embolization device with shield technology among all patients treated for intracranial aneurysms at our center. Methods This was a single-arm retrospective study of prospectively collected data of patients treated with pipeline embolization device with shield technology at our high-volume center between January 2018–January 2021. The primary efficacy endpoint was complete occlusion as measured by a class 1 Raymond-Roy score at 1-year and 2-year follow-up. The primary safety endpoint was major morbidity and neurological mortality up to 1 year following intervention. Results A total of 328 patients (mean age 56.1 ± 14.7 years; 81.1% female), 80 of whom were previously included in PEDESTRIAN, with 396 aneurysms, were analyzed. A total of 378 devices were deployed, with 93.9% (372/396) of aneurysms requiring only one device. Follow-up angiography was available for 90.2% (296/328) of the procedures after a mean time of 14.0 ± 8.2 months. Complete occlusion was demonstrated for 78.5% (132/168) of aneurysms at 12 months and 90.7% (98/108) at 24 months. The overall rates of major morbidity and neurological mortality after 2 years were 1.5% (5/328) and 0.6% (2/328), respectively. Conclusion Our results demonstrate high rates of complete long-term occlusion among patients treated with pipeline embolization device with shield technology. We also observed low rates of mortality and morbidity consistent with fewer thromboembolic complications with pipeline embolization devices with shield technology.

Funder

Medtronic, Inc.

Publisher

SAGE Publications

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3