Response control of a large transmission tower-line system under seismic excitations using friction dampers

Author:

Chen Bo1,Weng Shun2,Zhi Lunhai3,Li Dongming3

Affiliation:

1. Key Laboratory of Roadway Bridge and Structural Engineering, Wuhan University of Technology, Wuhan, China

2. School of Civil Engineering and Mechanics, Huazhong University of Science and Technology, Wuhan, China

3. School of Civil Engineering and Architecture, Wuhan University of Technology, Wuhan, China

Abstract

The transmission tower-line system is widely used in electric infrastructures across the world and generally possesses a small stiffness and low structural damping. The excessive vibration of a transmission tower-line system subjected to seismic excitations may induce a structural damage or failure. To avoid the excessive vibration under strong earthquakes, a large transmission tower-line system requires some measures to abate their dynamic responses. Friction damper is a solution to realize the response control of a transmission tower-line system. In this regard, the response mitigation and performance assessment on a transmission tower-line system with friction dampers under strong earthquakes are actively carried out in this study. The analytical model of a transmission line is proposed based on Hamilton’s variational statement of dynamics and Lagrange’s formulation. A two-dimensional lumped mass model of a transmission tower is developed for the dynamic analysis by simplifying the three-dimensional finite element model. The mechanical model of a friction damper is established by considering the effect of damper axial stiffness. The equations of motion and dynamic analytical method of a transmission tower-line system without/with friction dampers subjected to seismic excitations are proposed. In addition, the approach for assessing energy responses of a transmission tower-line system without/with friction dampers subjected to seismic excitations is also developed. A real transmission tower-line system is taken as an example to examine the feasibility of the proposed control approach. The parametric study is conducted to investigate the effects of damper control force, damper stiffness, earthquake intensity, and damper location. The made observations demonstrate that the implementation of friction dampers in a transmission tower-line system can substantially suppress the seismic responses with optimal damper parameters.

Funder

Chenguang Science and technology Plan of Wuhan

Natural Science Foundation of Hubei Province

National Natural Science Foundation of China

Publisher

SAGE Publications

Subject

Building and Construction,Civil and Structural Engineering

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3