Effect of Impaction Sequence on Osteochondral Graft Damage: The Role of Repeated and Varying Loads

Author:

Kang Richard W.1,Friel Nicole A.12,Williams James M.2,Cole Brian J.12,Wimmer Markus A.12

Affiliation:

1. Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois

2. Department of Anatomy and Cell Biology, Rush University Medical Center, Chicago, Illinois

Abstract

Background Osteochondral autografts and allografts require mechanical force for proper graft placement into the defect site; however, impaction compromises the tissue. This study aimed to determine the effect of impaction force and number of hits to seat the graft on cartilage integrity. Hypothesis Under constant impulse conditions, higher impaction load magnitudes are more detrimental to cell viability, matrix integrity, and collagen network organization and will result in proteoglycan loss and nitric oxide release. Study Design Controlled laboratory study. Methods Osteochondral explants, harvested from fresh bovine trochleae, were exposed to a series of consistent impact loads delivered by a pneumatically driven device. Each plug received the same overall impulse of 7 Ns, reflecting the mean of 23 clinically inserted plugs. Impaction loads of 37.5 N, 75 N, 150 N, and 300 N were matched with 74, 37, 21, and 11 hits, respectively. After impaction, the plugs were harvested, and cartilage was analyzed for cell viability, histology by safranin-O and picrosirius red staining, and release of sulfated glycosaminoglycans (GAGs) and nitric oxide. Data were compared with nonimpacted controls. Results Impacted plugs had significantly lower cell viability than nonimpacted plugs. A dose-response relationship in loss of cell viability with respect to load magnitude was seen immediately and after 4 days but lost after 8 days. Histological analysis revealed intact cartilage surface in all samples (loaded or control), with loaded samples showing alterations in birefringence. While the sulfated GAG release was similar across varying impaction loads, release of nitric oxide increased with increasing impaction magnitudes and time. Conclusion Impaction loading parameters have a direct effect on the time course of the viability of the cartilage in the graft tissue. Clinical Relevance Optimal loading parameters for surgical impaction of osteochondral grafts are those with lower load magnitudes and a greater number of hits to ensure proper fit.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 41 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3