Early Experience with the Sydney and EVT Prostheses for Endoluminal Treatment of Abdominal Aortic Aneurysms

Author:

May James1,White Geoffrey H.1,Yu Weiyun1,Waugh Richard C.1,Stephen Michael S.1,McGahan Timothy J.1,Harris John P.1

Affiliation:

1. Department of Vascular Surgery, Royal Prince Alfred Hospital, and the Department of Surgery, University of Sydney, Sydney, Australia

Abstract

Purpose: The aim of this study was to report early experiences with the Sydney and Endovascular Technologies (EVT) prostheses for the treatment of abdominal aortic aneurysms (AAA) deemed suitable for endoluminal tube graft repair. Methods: Consecutive endoluminal tube graft repairs were analyzed over the first 12 months in which the Sydney and EVT prostheses were used. Patients eligible for the EVT prosthesis had type I AAAs: a proximal neck length ≥ 2 cm, a distal cuff length ≥ 1.5 cm, and nontortuous iliac arteries ≥ 8 mm. Selection criteria for the Sydney device were more liberal and included AAAs that had distal cuffs < 1.5 cm. During the study period, 28 of 91 patients evaluated for AAA repair were thus selected for endoluminal grafting: 18 patients received the Sydney endograft and 10 the EVT device. Medical comorbidities were present in slightly less than one third of patients in both groups. Contrast-enhanced computerized tomography (CT) was performed preoperatively, within 10 days of operation, and at 6 and 12 months postprocedure. Results: All endografts were successfully deployed in both groups. Postprocedural CT scans revealed incomplete aneurysm exclusion in four patients with the Sydney endograft. Subsequent deployment of a second endograft sealed these “leaks” in two cases; the other two were converted to open repair (89% clinical success). No leaks were seen with the EVT device. Local/vascular complications occurred in 33% of the Sydney group compared with 20% for the EVT device (p = 0.001); systemic sequelae were more common in the EVT group (30% versus 17% in the Sydney cohort, p = 0.002). There were no deaths within 30 days; three late deaths were not procedure related. Conclusion: AAAs that are suitable for endoluminal tube graft repair may be treated with a high rate of initial success with either the Sydney or EVT prostheses. More liberal selection criteria may increase the likelihood of local/vascular complications.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3