A New Nonstented Balloon-Expandable Graft for Straight or Bifurcated Endoluminal Bypass

Author:

White Geoffrey H.,Yu Weiyun,May James,Stephen Michael S.,Waugh Richard C.1

Affiliation:

1. Department of Interventional Radiology, Royal Prince Alfred Hospital, University of Sydney, Sydney, Australia

Abstract

Purpose: The aim of this study was to determine the feasibility of endoluminal grafting of aneurysms using a new design of nonstented endograft. Methods: Initial studies were undertaken in bench models and by implantation of endografts into animal vessels. Between May 1992 and June 1994, endoluminal repair of aneurysms was undertaken in 47 patients (44 male, 3 female). A new balloon-expandable endoluminal graft was developed and has now been studied in 25 of these 47 cases. This graft does not require adjunctive use of a vascular stent because of its unique construction, which incorporates metallic implants (graft attachment device or “GAD”) into the graft material. The design is applicable to endovascular grafting of occlusive arterial disease, as well as aneurysms. All patients were investigated by duplex scan, calibrated angiogram, and angio-CT scan and then allocated into groups that we defined according to the following criteria: group I, considered suitable for transfemoral implantation of a straight tube graft (n = 12); group II, unsuitable for transfemoral tube graft because of short neck of aneurysm, absent distal neck, or diseased iliac arteries (n = 10); and group III, peripheral aneurysms (n = 3). All patients were followed by clinical examination, duplex scan, and CT scan, with selective use of angiography. Results: Intraluminal deployment of the graft was achieved in all 25 patients; however, 3 patients from group II subsequently required conversion to open procedures because of the following complications: (1) partial graft thrombosis resulting from inadvertent omission of systemic anticoagulation during deployment (n = 1); and (2) unsuccessful deployment of the contralateral limb of a bifurcated graft in the iliac artery (n = 2). Successful endoluminal repair was achieved in 100% of patients in groups I and III, compared to 70% in group II. Conclusions: These preliminary results (in a series of high-risk patients) have demonstrated that endoluminal abdominal aortic aneurysm repair with this graft can be achieved reliably and with low morbidity in patients who fulfill the selection criteria (group I) and in peripheral aneurysms (group III), but the results were less satisfactory in aneurysms that do not have a good proximal or distal neck or in patients with diseased iliac arteries (group II). Further modification of the bifurcated version of this graft design, together with improvements in access techniques and graft materials, is required for successful endoluminal grafting in a wider range of patients.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Cited by 22 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3