Author:
Li Dong,Lai Zhi-Chao,Wang Ying,Zheng Zhou-Lian
Abstract
The stiffness of membrane structures widely used in modern buildings is provided by pre-tension, which means that any loss of pre-tension during service life may endanger structural safety and lead to engineering accidents. Therefore, the pre-tension of membrane structures needs to
be estimated effectively and a corresponding estimation method is proposed in this study. Firstly, a theoretical model of a rectangular membrane structure is established using the constant deflection contour method (CDCM) to analytically derive a relationship between the pre-tension and the
frequency. Then, the pre-tension is calculated using the frequency obtained experimentally by non-contact modal testing using a three-dimensional digital image correlation (3D-DIC) technique. Furthermore, the estimation method is validated by experimental study. The results show that the proposed
method can provide a satisfactory assessment of the pre-tension in rectangular membrane structures and has significant potential to be utilised by industry.
Publisher
British Institute of Non-Destructive Testing (BINDT)
Subject
Materials Chemistry,Metals and Alloys,Mechanical Engineering,Mechanics of Materials
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献