Single-Laboratory Validation for the Determination of Cocoa Flavanols and Procyanidins (by Degree of Polymerization DP1–7) in Cocoa-Based Products by Hydrophilic Interaction Chromatography Coupled with Fluorescence Detection: First Action 2020.05

Author:

Bussy Ugo1,Hewitt Gregory1,Olanrewaju Yusuf1,May Brian R1,Anderson Nicholas1,Ottaviani Javier I12,Kwik-Uribe Catherine1

Affiliation:

1. Mars, Incorporated, 6885 Elm St, McLean, VA 22101, USA

2. University of California Davis, Department of Human Nutrition, CA 95616-5270, USA

Abstract

Abstract Background Flavanols and procyanidins are complex bioactives found in many foods such as cocoa. As their consumption is associated with health benefits, cocoa flavanols and procyanidins are receiving increasing attention from consumers, industry, researchers, and regulators. Objective The objective of this study is to validate a method using hydrophilic interaction chromatography (HILIC) with fluorescence detection (FLD) and a commercially available reference material for the determination of flavanols and procyanidins (CF) in cocoa-based products. Methods Method performances were evaluated for cocoa matrices with CF content that ranged from 0.8 to 500 mg/g, which included low CF matrices (milk and dark chocolate, cocoa powder, and liquor) and high CF matrices (cocoa extract and dietary supplement products). The method was validated in a single-laboratory by determining sensitivity, selectivity, linearity, stability, robustness, accuracy, and precision for each of the matrices. Results The method was validated for cocoa matrices with CF content that ranged from 0.8 to 500 mg/g. Accuracy ranged from 86 to 99% and repeatability (RSDr) from 1.5 to 8.6% for CF. Conclusions Analytical performances acquired through this single-laboratory validation study for a wide range of cocoa-based matrices demonstrate that this method is fit-for-purpose for the determination of flavanols and procyanidins in cocoa-based products. Highlights Hydrophilic interaction chromatography (HILIC) with fluorescence detection was successfully used to determine total CF content in multiple product types. Single-laboratory method validation results demonstrate that the method is fit for purpose for cocoa-based matrices containing <0.8 to 500 mg/g of CF.

Publisher

Oxford University Press (OUP)

Subject

Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3