UPLC–MS-Based Procedures to Detect Prolyl-Hydroxylase Inhibitors of HIF in Urine

Author:

Mazzarino Monica1,Perretti Ilaria1,Stacchini Carlotta12,Comunità Fabio1,de la Torre Xavier1,Botrè Francesco13

Affiliation:

1. Laboratorio Antidoping, Federazione Medico Sportiva Italiana, Largo Giulio Onesti, 1, Rome 00197, Italy

2. Dipartimento di Chimica e Tecnologia del Farmaco, ‘Sapienza’ Università di Roma, Piazzale Aldo Moro 5, Rome 11085, Italy

3. Dipartimento di Medicina Sperimentale, “Sapienza” Università di Roma, Viale Regina Elena, 324, Rome 00161, Italy

Abstract

Abstract This article presents newly developed screening and confirmation analytical procedures to detect the misuse of nine prolyl-hydroxylase inhibitors of the hypoxia-inducible factor: daprodustat, desidustat, FG2216, IOX2, IOX4, JNJ-42041935, molidustat, roxadustat and vadadustat, targeting either the parent drugs and/or their main metabolite(s). For the sample pretreatment, different extraction protocols and technologies were evaluated. The instrumental analysis was performed by ultra-high-performance liquid chromatography coupled to either high- or low-resolution mass spectrometry. The chromatographic separation was performed on a C18 column, employing water and acetonitrile, both containing 0.1% formic acid, as mobile phase. Detection was achieved using as analyzer either a triple quadrupole or an Orbitrap, with positive and negative electrospray ionization and different acquisition modes. Validation of the procedures was performed according to the ISO 17025 and World Anti-Doping Agency guidelines. The methods do not show any significant interference at the retention times of the analytes of interest. The extraction efficiency was estimated to be greater than 75% for all analytes and the matrix effect smaller than 35%. Detection capability was determined in the range of 0.25–2.0 for the screening procedure and in the range of 0.5–2.0 ng/mL for the confirmation procedure, that is, in a range of concentration small enough to reveal the abuse of the compounds considered, in case they are used as performance-enhancing agents. The repeatability of the relative retention times (CV% < 0.5) and of the relative abundances of the selected ion transitions, considered only in the case of triple quadrupole (CV% < 15), was confirmed to be fit for purpose to ensure the unambiguous identification of all the target analytes in human urine. The applicability of the newly developed methods was verified by the analysis of urine samples containing molidustat, roxadustat or daprodustat. The developed procedures enabled to detect the compounds under investigation and their main metabolites.

Funder

Italian Department of Health

Ministero della Salute, Commissione per la vigilanza sul doping e sulla tutela sanitaria delle attività sportive

Publisher

Oxford University Press (OUP)

Subject

Chemical Health and Safety,Health, Toxicology and Mutagenesis,Toxicology,Environmental Chemistry,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3