Assessing radiation dose limits for X-ray fluorescence microscopy analysis of plant specimens

Author:

Jones Michael W M1,Kopittke Peter M2,Casey Lachlan3,Reinhardt Juliane4,Blamey F Pax C2,van der Ent Antony5

Affiliation:

1. Central Analytical Research Facility, Institute for Future Environments, Queensland University of Technology, Australia

2. School of Agriculture and Food Sciences, The University of Queensland, Australia

3. Centre for Microscopy and Microanalysis, The University of Queensland, Australia

4. Australian Synchrotron, ANSTO, Australia

5. Sustainable Minerals Institute, The University of Queensland, Australia

Abstract

Abstract Background and Aims X-ray fluorescence microscopy (XFM) is a powerful technique to elucidate the distribution of elements within plants. However, accumulated radiation exposure during analysis can lead to structural damage and experimental artefacts including elemental redistribution. To date, acceptable dose limits have not been systematically established for hydrated plant specimens. Methods Here we systematically explore acceptable dose rate limits for investigating fresh sunflower (Helianthus annuus) leaf and root samples and investigate the time–dose damage in leaves attached to live plants. Key Results We find that dose limits in fresh roots and leaves are comparatively low (4.1 kGy), based on localized disintegration of structures and element-specific redistribution. In contrast, frozen-hydrated samples did not incur any apparent damage even at doses as high as 587 kGy. Furthermore, we find that for living plants subjected to XFM measurement in vivo and grown for a further 9 d before being reimaged with XFM, the leaves display elemental redistribution at doses as low as 0.9 kGy and they continue to develop bleaching and necrosis in the days after exposure. Conclusions The suggested radiation dose limits for studies using XFM to examine plants are important for the increasing number of plant scientists undertaking multidimensional measurements such as tomography and repeated imaging using XFM.

Publisher

Oxford University Press (OUP)

Subject

Plant Science

Reference37 articles.

1. Soft X-ray radiation-damage studies in PMMA using a cryo-STXM;Beetz;Journal of Synchrotron Radiation,2002

2. Synchrotron-based techniques shed light on mechanisms of plant sensitivity and tolerance to high manganese in the root environment;Blamey;Plant Physiology,2015

3. Time-resolved X-ray fluorescence analysis of element distribution and concentration in living plants: an example using manganese toxicity in cowpea leaves;Blamey;Environmental and Experimental Botany,2018

4. Micro-PIXE analysis: importance of biological sample preparation techniques;Budka;Radiation Physics and Chemistry,2004

5. Freeze-substitution methods for Ni localization and quantitative analysis in Berkheya coddii leaves by means of PIXE;Budka;Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms,2005