Sustaining Mammography Image Quality With a Technologist Coaching Program in the Era of the Enhancing Quality Using the Inspection Program (EQUIP)

Author:

Kozlov Andrew1ORCID,Larson David2,DeMartini Wendy B2,Pal Sunita2,Cowart Patricia3,Strain Audrey3,Ikeda Debra M2

Affiliation:

1. University of Utah School of Medicine, Department of Radiology and Imaging Sciences , Salt Lake City, UT , USA

2. Stanford University School of Medicine, Department of Radiology , Stanford, CA , USA

3. Stanford Healthcare , Stanford, CA , USA

Abstract

Abstract Objective To evaluate the ability of a long-term technologist coaching program to sustain gains in mammography quality made by a previously implemented quality improvement (QI) initiative. Methods Mammography quality metrics from July 2014 to June 2020 were reviewed. Numbers of screening mammograms performed/audited, monthly average mammogram overall quality pass rates, changes in facilities/staffing, and technical recall rates were evaluated. Performance metrics at baseline (July 2013), during the improvement (July 2014 to January 2015), postimprovement (February 2015 to August 2015), and sustained coaching periods (after initiation of the technologist coaching model, from September 2015 to June 2020) were compared. Results During the postimprovement and sustained coaching periods, 93% (501/541) and 90% (8902/9929) of audited mammograms, respectively, met overall passing criteria, achieving or exceeding the QI goal of 90%, and results for both periods were significantly higher than that during the improvement period (74%, 1098/1489), at P < 0.0001 and P < 0.0001, respectively. The technical recall rates during the improvement and postimprovement periods were 2.6% (85/3321) and 1.7% (54/3236), respectively; the rate during the sustained coaching period was significantly lower than these, at 1.2% (489/40 440) (P < 0.0001 and P = 0.0232, respectively). Sustained quality passing rates and lower technical recall rates were observed despite statistically significantly increases in screening volumes. Conclusion A technologist coaching program resulted in sustained high mammographic quality for almost 5 years.

Publisher

Oxford University Press (OUP)

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Calcifications, Cryoablation, and Much More;Journal of Breast Imaging;2023-11-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3