Clinical Image Quality in Daily Practice of Breast Cancer Mammography Screening

Author:

Guertin Marie-Hélène1,Théberge Isabelle1,Dufresne Michel-Pierre2,Zomahoun Hervé Tchala Vignon3,Major Diane1,Tremblay Richard4,Ricard Carmen5,Shumak Rene6,Wadden Nancy7,Pelletier Éric1,Brisson Jacques89

Affiliation:

1. Institut National de Santé Publique du Quebec, Québec, Québec, Canada

2. Hôpital Maisonneuve-Rosemont, Montréal, Québec, Canada

3. Centre de Recherche du CHU de Québec, Axe Santé des populations et pratiques optimales en santé, Québec, Québec, Canada

4. Ministère de la Santé et des Services sociaux, Québec, Québec, Canada

5. Clinique Radiologique Audet Inc, Québec, Québec, Canada

6. Cancer Care Ontario, Toronto, Ontario, Canada

7. Memorial University, Faculty of Medicine, St John's, Newfoundland, Canada

8. Centre de Recherche du CHU de Québec, Axe Oncologie, Québec, Québec, Canada

9. Département de Médecine Sociale et Préventive, Faculté de médicine and Centre de Recherche sur le cancer, Université Laval, Québec, Québec, Canada

Abstract

Objective To assess the quality of screening mammograms performed in daily practice in the Quebec Breast Cancer Screening Program. Subjects and Methods Clinical image quality of a random subsample of 197 screening mammograms performed in 2004-2005 was independently evaluated by 2 radiologists based on the criteria by Canadian Association of Radiologists (CAR). When disagreement occurred for overall judgement or positioning score, the mammograms were reviewed by a third radiologist. Cohen's kappas for interrater agreement were computed. Multivariable robust Poisson regression models were used to study associations of overall quality and positioning with body mass index (BMI) and breast density. Results The CAR criteria were not satisfied for 49.7% of the mammograms. Positioning was the quality attribute most often deficient, with 37.2% of mammograms failing positioning. Interrater agreement ranged from slight (kappa = 0.02 for compression and sharpness) to fair (kappa = 0.30 for exposure). For overall quality, women with a BMI ≥ 30 kg/m2 had a failure proportion of 67.5% compared with 34.9% for women with a BMI<25 kg/m2 (risk ratio 2.1 [95% confidence interval, 1.5-3.0]). For positioning, women with a BMI ≥ 30 kg/m2 had a failure proportion of 53.8% compared with 27.9% for women with a BMI < 25 kg/m2 (risk ratio 1.9 [95% confidence interval, 1.2-3.1]). Effects of breast density on image quality differed among radiologists. Conclusion Despite measures to ensure high-quality imaging, including CAR accreditation, approximately half of this random sample of screening mammograms failed the CAR quality standards. It would be important to define quality targets for screening mammograms carried out in daily practice to interpret such observations.

Funder

Canadian Institutes of Health Research

Canadian Breast Cancer Research Alliance

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3