COMPARISON OF RADIATION EXPOSURE TO THE PATIENT AND CONTRAST DETAIL RESOLUTIONS ACROSS LOW DOSE 2D/3D SLOT SCANNER AND TWO CONVENTIONAL DIGITAL RADIOGRAPHY X-RAY IMAGING SYSTEMS

Author:

Abdi Ahmed Jibril1ORCID,Mussmann Bo23ORCID,Mackenzie Alistair4ORCID,Klaerke Benedikte1,Andersen Poul Erik23

Affiliation:

1. Region of Southern Denmark, Clinical Engineering Department, Area of Diagnostic Radiology, B. Winsløws Vej 4, Indgang 34, Odense C, Denmark

2. Department of Radiology, Odense University Hospital, Odense C, Denmark

3. Department of Clinical Research, University of Southern Denmark, Odense C, Denmark

4. National Coordinating Centre for the Physics of Mammography, Royal Surrey County Hospital, Guildford, United Kingdom

Abstract

Abstract Purpose To assess and compare the radiation dose and image quality of the low dose 2D/3D EOS slot scanner (LDSS) to conventional digital radiography (DR) X-ray imaging systems for chest and knee examination protocols. Methods and materials The effective doses (ED) to the patient in the chest and knee clinical examination protocols for LDSS and DR X-ray imaging systems were determined using the dose area product and PCXMC Monte Carlo simulation software. The CDRAD phantom was imaged with 19 cm, and 13 cm thick Polymethyl Methacrylate (PMMA) blocks to simulate the chest and knees respectively of a patient of average adult size. The contrast detail resolution was calculated using image analysis software. Results The EDs for the LDSS default setting were up to 69% and 51% lower than for the DR systems for the chest (speed 4) and knee (speed 6) protocols, respectively, while for the increased dose level setting then the EDs were up to 42% and 35% lower than for the DR systems for the chest (speed 6) and knee (speed 8) protocols respectively. At the default setting, the contrast detail was lowest for the default setting of the 2D/3D low dose slot scanner (LDSS) for both chest and knee examinations, but at the highest dose levels then the threshold were equal or higher than the contrast resolution of DR imaging systems. Conclusion The LDSS has the potential to be used for clinical diagnosis of chest and knee examinations using the higher dose level. For speed 6 in chest protocol and speed 8 in knee protocol, the measured contrast detail resolution was comparable with the DR systems but at a lower effective dose.

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3