Long-term follow-up of abandoned transvenous defibrillator leads: a nationwide cohort study

Author:

Elgaard Anders Fyhn1ORCID,Johansen Jens Brock2,Nielsen Jens Cosedis3,Gerdes Christian3ORCID,Riahi Sam14,Philbert Berit Thornvig5,Haarbo Jens6,Melchior Thomas Maria7,Larsen Jacob Moesgaard1

Affiliation:

1. Department of Cardiology, Aalborg University Hospital, Hobrovej 18-20, 9000 Aalborg, Denmark

2. Department of Cardiology, Odense University Hospital, Odense, Denmark

3. Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark

4. Department of Clinical Medicine, Aalborg University Hospital, Aalborg, Denmark

5. Department of Cardiology, The Heart Center, Rigshospitalet, Copenhagen, Denmark

6. Department of Cardiology, Gentofte Hospital, Hellerup, Denmark

7. Department of Cardiology, Zealand University Hospital, Roskilde, Denmark

Abstract

Abstract Aims  Commonly, a dysfunctional defibrillator lead is abandoned and a new lead is implanted. Long-term follow-up data on abandoned leads are sparse. We aimed to investigate the incidence and reasons for extraction of abandoned defibrillator leads in a nationwide cohort and to describe extraction procedure-related complications. Methods and results  All abandoned transvenous defibrillator leads were identified in the Danish Pacemaker and ICD Register from 1991 to 2019. The event-free survival of abandoned defibrillator leads was studied, and medical records of patients with interventions on abandoned defibrillator leads were audited for procedure-related data. We identified 740 abandoned defibrillator leads. Meantime from implantation to abandonment was 7.2 ± 3.8 years with mean patient age at abandonment of 66.5 ± 13.7 years. During a mean follow-up after abandonment of 4.4 ± 3.1 years, 65 (8.8%) abandoned defibrillator leads were extracted. Most frequent reason for extraction was infection (pocket and systemic) in 41 (63%) patients. Procedural outcome after lead extraction was clinical success in 63 (97%) patients. Minor complications occurred in 3 (5%) patients, and major complications in 1 (2%) patient. No patient died from complication to the procedure during 30-day follow-up after extraction. Conclusion  More than 90% of abandoned defibrillator leads do not need to be extracted during long-term follow-up. The most common indication for extraction is infection. Abandoned defibrillator leads can be extracted with high clinical success rate and low risk of major complications at high-volume centres.

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3