Degree of Vinyl Conversion, Polymerization Shrinkage and Stress Development in Experimental Endodontic Composite

Author:

O'Donnell Justin N.R.1,Skrtic Drago1

Affiliation:

1. National Institute of Standards and Technology

Abstract

This study explores degree of vinyl conversion (DVC), polymerization shrinkage (PS) and shrinkage stress (PSS) of the experimental amorphous calcium phosphate (ACP) composites intended for use as an endodontic sealer. Light-cure (LC), chemical cure (CC) or dual-cure (DC; combined light and chemical cure) resins comprised urethane dimethacrylate (UDMA), 2-hydroxyethyl methacrylate (HEMA), methacryloyloxyethyl phthalate (MEP) and a high molecular mass oligomeric co-monomer, poly(ethyleneglycol)-extended UDMA (PEG-U) (designated UPHM resin). To fabricate composites, a mass fraction of 60 % UPHM resin was blended with a mass fraction of 40 % as-made (am-ACP) or ground ACP (g-ACP). DVC values of copolymer (unfilled UPHM resin) and composite specimens were determined by infrared spectroscopy. Glass-filled composites were used as controls. PS and PSS of composites were determined by dilatometry and tensometry, respectively. LC copolymers attained extraordinary high DVC values at 24 h post-cure (95.7 %), compared to CC (52 %) and DC (79.3 %) copolymer specimens. While the DVC values of LC and DC am-ACP composites were reduced between 5 and 10 %, DVC values of DC g-ACP composites increased almost 8 % compared to the corresponding copolymers. High DVC attained in LC composites was, expectedly, accompanied with high PS values (on average 7 vol%). However, PSS developed in LC and especially DC composites did not exceed PSS values seen in other UDMA-based composites. Based on this initial evaluation, it is concluded that, DC, g-ACP filled UPHM composite shows promise as an endodontic sealer. However, further physicochemical evaluations, including water sorption, mechanical stability and ion release as well as a leachability studies need to be performed before this experimental material is tested for cellular responses and, eventually recommended for clinical utility.

Publisher

Trans Tech Publications, Ltd.

Subject

Biomedical Engineering,Bioengineering,Biotechnology

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3