Frame-based and robot-assisted insular stereo-electroencephalography via an anterior or posterior oblique approach

Author:

Machetanz Kathrin12,Grimm Florian12,Wuttke Thomas V.13,Kegele Josua3,Lerche Holger3,Tatagiba Marcos1,Rona Sabine1,Gharabaghi Alireza12,Honegger Jürgen1,Naros Georgios12

Affiliation:

1. Department of Neurosurgery;

2. Division of Functional and Restorative Neurosurgery, Department of Neurosurgery; and

3. Department of Epileptology, Eberhardt Karls University, Tuebingen, Germany

Abstract

OBJECTIVE There is an increasing interest in stereo-electroencephalography (SEEG) for invasive evaluation of insular epilepsy. The implantation of insular SEEG electrodes, however, is still challenging due to the anatomical location and complex functional segmentation in both an anteroposterior and ventrodorsal (i.e., superoinferior) direction. While the orthogonal approach (OA) is the shortest trajectory to the insula, it might insufficiently cover these networks. In contrast, the anterior approach (AOA) or posterior oblique approach (POA) has the potential for full insular coverage, with fewer electrodes bearing a risk of being more inaccurate due to the longer trajectory. Here, the authors evaluated the implantation accuracy and the detection of epilepsy-related SEEG activity with AOA and POA insular trajectories. METHODS This retrospective study evaluated the accuracy of 220 SEEG electrodes in 27 patients. Twelve patients underwent a stereotactic frame-based procedure (frame group), and 15 patients underwent a frameless robot-assisted surgery (robot group). In total, 55 insular electrodes were implanted using the AOA or POA considering the insular anteroposterior and ventrodorsal functional organization. The entry point error (EPE) and target point error (TPE) were related to the implantation technique (frame vs robot), the length of the trajectory, and the location of the target (insular vs noninsular). Finally, the spatial distribution of epilepsy-related SEEG activity within the insula is described. RESULTS There were no significant differences in EPE (mean 0.9 ± 0.6 for the nonsinsular electrodes and 1.1 ± 0.7 mm for the insular electrodes) and TPE (1.5 ± 0.8 and 1.6 ± 0.9 mm, respectively), although the length of trajectories differed significantly (34.1 ± 10.9 and 70.1 ± 9.0 mm, repsectively). There was a significantly larger EPE in the frame group than in the robot group (1.5 ± 0.6 vs 0.7 ± 0.5 mm). However, there was no group difference in the TPE (1.5 ± 0.8 vs 1.6 ± 0.8 mm). Epilepsy-related SEEG activity was detected in 42% (23/55) of the insular electrodes. Spatial distribution of this activity showed a clustering in both anteroposterior and ventrodorsal directions. In purely insular onset cases, subsequent insular lesionectomy resulted in a good seizure outcome. CONCLUSIONS The implantation of insular electrodes via the AOA or POA is safe and efficient for SEEG implantation covering both anteroposterior and ventrodorsal functional organization with few electrodes. In this series, there was no decrease in accuracy due to the longer trajectory of insular SEEG electrodes in comparison with noninsular SEEG electrodes. The results of frame-based and robot-assisted implantations were comparable.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3