Accuracy of Boltless Frame-Based Stereo-Electroencephalography Electrode Implantation

Author:

Fujita Yuya12,Khoo Hui Ming12ORCID,Kimoto Yuki12,Emura Takuto12,Iwata Takamitsu12,Matsuhashi Takahiro12,Miura Shimpei12,Yanagisawa Takufumi12,Hosomi Koichi12,Tani Naoki12,Oshino Satoru12,Hirata Masayuki12,Kishima Haruhiko12

Affiliation:

1. Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan;

2. Epilepsy Center, Osaka University Hospital, Suita, Japan

Abstract

BACKGROUND AND OBJECTIVES: Boltless implantation of stereo-electroencephalography electrode is a useful alternative especially when anchor bolt is not available such as in country with limited resources or is less appropriate such as placement in patients with thin skull or at the occiput area, despite some drawbacks including potential dislodgement. While the accuracy of implantation using anchor bolt is well-studied, data on boltless implantation remain scarce. This study aimed to reveal the accuracy, permissible error for actual placement of electrodes within the grey matter, and delayed electrode dislodgement in boltless implantation. METHODS: A total of 120 electrodes were implanted in 15 patients using a Leksell Stereotactic G Frame with each electrode fixed on the scalp using sutures. Target point error was defined as the Euclidean distance between the planned target and the electrode tip on immediate postimplantation computed tomography. Similarly, delayed dislodgement was defined as the Euclidean distance between the electrode tips on immediate postimplantation computed tomography and delayed MRI. The factors affecting accuracy were evaluated using multiple linear regression. The permissible error was defined as the largest target point error that allows the maximum number of planned gray matter electrode contacts to be actually placed within the gray matter as intended. RESULTS: The median (IQR) target point error was 2.6 (1.7-3.5) mm, and the permissible error was 3.2 mm. The delayed dislodgement, with a median (IQR) of 2.2 (1.4-3.3) mm, was dependent on temporal muscle penetration (P = 5.0 × 10−4), scalp thickness (P < 5.1 × 10−3), and insertion angle (P = 3.4 × 10−3). CONCLUSION: Boltless implantation of stereo-electroencephalography electrode offers an accuracy comparable to those using anchor bolt. During the planning of boltless implantation, target points should be placed within 3.2 mm from the gray-white matter junction and a possible delayed dislodgement of 2.2 mm should be considered.

Funder

Ministry of Education, Culture, Sports, Science and Technology

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3