The Value of SINO Robot and Angio Render Technology for Stereoelectroencephalography Electrode Implantation in Drug-Resistant Epilepsy

Author:

Dai Yihai1,Jiang Rifeng2,Zhang Jingyi1,Qian Zhe1ORCID,Chen Zhen1,Shi Songsheng1,Song Shiwei1

Affiliation:

1. Department of Neurosurgery, Fujian Medical University Union Hospital, Fuzhou, Fujian, China

2. Department of Imaging, Fujian Medical University Union Hospital, Fuzhou, Fujian, China

Abstract

Abstract Background Stereoelectroencephalography (SEEG) electrodes are implanted using a variety of stereotactic technologies to treat refractory epilepsy. The value of the SINO robot for SEEG electrode implantation is not yet defined. The aim of the current study was to assess the value of the SINO robot in conjunction with Angio Render technology for SEEG electrode implantation and to assess its efficacy. Methods Between June 2018 and October 2020, 58 patients underwent SEEG electrode implantation to resect or ablate their epileptogenic zone (EZ). The SINO robot and the Angio Render technology was used to guide the electrodes and visualize the individual vasculature in a three-dimensional (3D) fashion. The 3D view functionality was used to increase the safety and accuracy of the electrode implantation, and for reducing the risk of hemorrhage by avoiding blood vessels. Results In this study, 634 SEEG electrodes were implanted in 58 patients, with a mean of 10.92 (range: 5–18) leads per patient. The mean entry point localization error (EPLE) was 0.94 ± 0.23 mm (range: 0.39–1.63 mm), and the mean target point localization error (TPLE) was 1.49 ± 0.37 mm (range: 0.80–2.78 mm). The mean operating time per lead (MOTPL) was 6. 18 ± 1.80 minutes (range: 3.02–14.61 minutes). The mean depth of electrodes was 56.96 ± 3.62 mm (range: 27.23–124.85 mm). At a follow-up of at least 1 year, in total, 81.57% (47/58) patients achieved an Engel class I seizure freedom. There were two patients with asymptomatic intracerebral hematomas following SEEG electrode placement, with no late complications or mortality in this cohort. Conclusions The SINO robot in conjunction with Angio Render technology-in SEEG electrode implantation is safe and accurate in mitigating the risk of intracranial hemorrhage in patients suffering from drug-resistant epilepsy.

Funder

Fujian Provincial Natural Science Foundation Program

The Startup Fund for scientific research, Fujian Medical University

Joint Funds for the Innovation of Science and Technology, Fujian province

Publisher

Georg Thieme Verlag KG

Reference47 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3