A Two-Minute Walking Test With a Smartphone App for Persons With Multiple Sclerosis: Validation Study

Author:

van Oirschot PimORCID,Heerings MarcoORCID,Wendrich KarineORCID,den Teuling BramORCID,Dorssers FrankORCID,van Ee RenéORCID,Martens Marijn BartORCID,Jongen Peter JosephORCID

Abstract

Background Walking disturbances are a common dysfunction in persons with multiple sclerosis (MS). The 2-Minute Walking Test (2MWT) is widely used to quantify walking speed. We implemented a smartphone-based 2MWT (s2MWT) in MS sherpa, an app for persons with MS. When performing the s2MWT, users of the app are instructed to walk as fast as safely possible for 2 minutes in the open air, while the app records their movement and calculates the distance walked. Objective The aim of this study is to investigate the concurrent validity and test-retest reliability of the MS sherpa s2MWT. Methods We performed a validation study on 25 persons with relapsing-remitting MS and 79 healthy control (HC) participants. In the HC group, 21 participants were matched to the persons with MS based on age, gender, and education and these followed the same assessment schedule as the persons with MS (the HC-matched group), whereas 58 participants had a less intense assessment schedule to determine reference values (the HC-normative group). Intraclass correlation coefficients (ICCs) were determined between the distance measured by the s2MWT and the distance measured using distance markers on the pavement during these s2MWT assessments. ICCs were also determined for test-retest reliability and derived from 10 smartphone tests per study participant, with 3 days in between each test. We interviewed 7 study participants with MS regarding their experiences with the s2MWT. Results In total, 755 s2MWTs were completed. The adherence rate for the persons with MS and the participants in the HC-matched group was 92.4% (425/460). The calculated distance walked on the s2MWT was, on average, 8.43 m or 5% (SD 18.9 m or 11%) higher than the distance measured using distance markers (n=43). An ICC of 0.817 was found for the concurrent validity of the s2MWT in the combined analysis of persons with MS and HC participants. Average ICCs of 9 test-retest reliability analyses of the s2MWT for persons with MS and the participants in the HC-matched group were 0.648 (SD 0.150) and 0.600 (SD 0.090), respectively, whereas the average ICC of 2 test-retest reliability analyses of the s2MWT for the participants in the HC-normative group was 0.700 (SD 0.029). The interviewed study participants found the s2MWT easy to perform, but they also expressed that the test results can be confronting and that a pressure to reach a certain distance can be experienced. Conclusions The high correlation between s2MWT distance and the conventional 2MWT distance indicates a good concurrent validity. Similarly, high correlations underpin a good test-retest reliability of the s2MWT. We conclude that the s2MWT can be used to measure the distance that the persons with MS walk in 2 minutes outdoors near their home, from which both clinical studies and clinical practice can benefit.

Publisher

JMIR Publications Inc.

Subject

Computer Science Applications,Health Informatics,Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3