Disinfection of Needleless Catheter Connectors and Access Ports With Alcohol May Not Prevent Microbial Entry: The Promise of a Novel Antiseptic-Barrier Cap

Author:

Menyhay Steve Z.,Maki Dennis G.

Abstract

Background.Needleless valve connectors for vascular catheters are widely used throughout the United States because they reduce the risk of biohazardous injuries from needlesticks and exposure to bloodborne pathogens, such as human immunodeficiency virus and hepatitis C virus. Patients with long-term central venous catheters are at significant risk of acquiring catheter-related bloodstream infections caused by microbes that gain access through the connection between the administration set and the catheter or an injection port. Most healthcare practitioners wipe the membranous septum of the needleless connector or the injection port with 70% alcohol before accessing it. We report a simulation study of the efficacy of conventional alcohol disinfection before access, compared with that of a novel antiseptic-barrier cap that, when threaded onto a needleless luer-activated valved connector, allows a chlorhexidine-impregnated sponge to come into continuous contact with the membranous surface; after removal of the cap, there is no need to disinfect the surface with alcohol before accessing it.Methods.One hundred five commercial, needleless luer-activated valved connectors, each accessible by a blunt male-connector luer-lock attachment, were purchased from 3 manufacturers and were tested. The membranous septum of each test device was first heavily contaminated with ~105colony-forming units ofEnterococcus faecalisand then was allowed to dry for 24 hours. Fifteen of the contaminated devices were not disinfected (positive controls), 30 were conventionally disinfected with a commercial 70% alcohol pledget, and 60 had the antiseptic cap threaded onto the connector and then removed after 10 minutes. The test connectors were then accessed with a sterile syringe containing nutrient broth media, which was injected, captured on the downstream side of the intraluminal fluid pathway, and cultured quantitatively.Results.All 15 control connectors (100%) showed massive transmission of microorganisms across the membranous septum (4,500-10,000 colony-forming units). Of the 30 connectors accessed after conventional disinfection with 70% alcohol, 20 (67%) showed transmission of microorganisms (442-25,000 colony-forming units). In contrast, of the 60 connectors cultured after application of the novel antiseptic cap, only 1 (1.6%) showed any transmission of microorganisms (P<.001).Conclusions.The findings of this study show that, if the membranous septum of a needleless luer-activated connector is heavily contaminated, conventional disinfection with 70% alcohol does not reliably prevent entry of microorganisms. In contrast, the antiseptic-barrier cap provided a high level of protection, even in the presence of very heavy contamination. This novel technology deserves to be studied in a clinical trial.

Publisher

Cambridge University Press (CUP)

Subject

Infectious Diseases,Microbiology (medical),Epidemiology

Cited by 96 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3