Affiliation:
1. Department of Pediatrics, Schneider Children's Hospital of Long Island Jewish Medical Center, New Hyde Park, New York 11042.
Abstract
The vascular catheter hub is a potential portal of entry for microorganisms that cause catheter-related sepsis. Thus, a reduction in catheter hub contamination might reduce the incidence of catheter-related sepsis. To develop a regimen suitable for reducing microbial contamination of the catheter hub, we experimentally contaminated catheter hubs and assessed the efficacies of disinfectant solutions. Catheter hubs were incubated overnight with suspensions of Staphylococcus epidermidis, Pseudomonas aeruginosa, or Candida parapsilosis. After removal of unattached microorganisms, the catheter hubs were swabbed by rotating cotton swabs dipped in 1% chlorhexidine, 1% chlorhexidine in 70% ethanol, 70% ethanol, 97% ethanol, or normal saline. Posttreatment swabs of the catheter hub were obtained and cultured quantitatively. The cleaning regimens containing ethanol were the most effective. Seventy percent ethanol was more effective than chlorhexidine and is likely to be the safest treatment. We conclude that cleaning of the catheter hub with disinfectant can dramatically reduce microbial contamination.
Publisher
American Society for Microbiology
Cited by
112 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献