Evaluation of a New Combined Transcutaneous Measurement of Pco2/Pulse Oximetry Oxygen Saturation Ear Sensor in Newborn Patients

Author:

Bernet-Buettiker Vera1,Ugarte Maria J.1,Frey Bernhard1,Hug Maja Isabelle1,Baenziger Oskar1,Weiss Markus2

Affiliation:

1. Departments of Neonatology and Intensive Care

2. Anaesthesia, University Children's Hospital, Zurich, Switzerland

Abstract

Objective. Arterial oxygen saturation (Sao2) and arterial carbon dioxide partial pressure (Paco2) are 2 of the most important respiratory parameters in the treatment of critically ill neonates. Noninvasive monitoring of these parameters is desirable for continuous estimating of the respiratory status and reducing blood loss because of repeated blood gas analyses. Transcutaneous measurement of Pco2 (Ptcco2) represents a simple and noninvasive technique for continuous monitoring of ventilation. However, sensor preparation, positioning, taping, and repeated changes of the sensor location make the handling difficult and complicate its use in the neonatal care unit. Recently, a new sensor for combined assessment of pulse oximetry oxygen saturation (Spo2) and Ptcco2 has been introduced (TOSCA Monitor; Linde Medical Sensors, Basel, Switzerland). The monitor combines pulse oximetry and Ptcco2 measurement in a single ear sensor, which works at 42°C to enhance blood flow in capillaries below the sensor. Methods. In a prospective, open, nonrandomized study of 60 ill neonates, the new ear sensor for combined assessment of Spo2 and Ptcco2 at 42°C was tested. The sensor was adapted to the ear of a neonate with a Varihesive layer (Conva Tec; Princeton, NJ). Data obtained from the ear sensor were compared with Spo2 Finger/Heel, Sao2, and Paco2 obtained from arterial blood gas in 30 patients and with a capillary blood gas in an additional 30 patients using Bland Altman bias analysis. Data are presented as median (range). Results. The postconceptional age of the patients was 38.3 weeks (range: 28 5/7–40 5/7) in the arterial group and 37.9 weeks (range: 29 6/7–41 0/7) in the capillary group. Age of the newborns studied was 3.5 days (range: 1–28) in the arterial blood sample group (n = 30) and 6 days (range: 2–28) in the capillary blood sample group (n = 30). Patient weight was 3.02 kg (range: 1.5–4.5) in the arterial group and 2.76 kg (range: 1.0–3.71) in the other group. Three patients had weights of <1500 g. Twenty-one of 60 patients were conventionally ventilated, 4 patients received high-frequency oscillation, and 35 were not ventilated. Mean difference (bias) and precision (2 SD of the mean difference) between Ptcco2 TOSCA and Paco2 were −0.44 kPa (−3.21 mm Hg) and 0.82 kPa (6.02 mm Hg) and between Ptcco2 TOSCA and Pcapco2 were −0.09 kPa (−0.67 mm Hg) and 1.11 kPa (8.07 mm Hg), respectively. Spo2 assessment by the TOSCA revealed slightly higher values compared with Sao2 (bias: −0.48%), whereas Spo2 Finger/Heel values were slightly lower than Sao2 (bias: 0.52%). Conclusion. The TOSCA monitor with the ear sensor adapted to ears of neonates allows reliable estimation of Sao2 and Paco2. A potential benefit is the reduction in motion artifacts because of less head movement in newborns and that only a single cable leads form the patient to the monitor. In addition, the sensor is not removed for chest radiograph or for nursing the infant on his or her parent's lap. Long-term studies in a large population with continuous measurements are required to confirm these preliminary findings and to elucidate the benefits in detection of respiratory deterioration and the potential side effects of this sensor.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3