A Comparison of Two Transcutaneous Monitors for the Measurement of Arterial Po2 and Pco2 in Neonates

Author:

Carter B.12,Hochmann M.12,Osborne A.12,Nisbet A.12,Campbell N.13

Affiliation:

1. Royal Children's Hospital, Melbourne, Victoria

2. Intensive Care Technologist, Paediatric and Neonatal Intensive Care Unit.

3. Neonatal Intensive Care Unit.

Abstract

We examined the ability of two transcutaneous devices (Fastrac, Sensormedics Corporation, Yorba Linda, California, U.S.A. and Hewlett Packard M1018A, Hewlett Packard Component Monitoring System, Hewlett Packard, North Hollywood, U.S.A.) to measure arterial Pco2 and Po2 in neonates. Thirty-seven neonates had transcutaneous oxygen measured with the Hewlett Packard (HPo2 group), 38 neonates had transcutaneous carbon dioxide measured with the Hewlett Packard (HPco2 group) and the Fastrac was used on 27 neonates (FTco2 group). Both devices were operated with electrode temperatures of 43.5 °C although an additional ten subjects were studied using the Fastrac with an electrode temperature of 43.0°C. The mean differences (transcutaneous—arterial) and upper and lower limits of agreement were calculated for each group. For the HPo2 group they were 3.78 mmHg (-12.23 to 19.80 mmHg), for the HPco2 group they were 0.40 mmHg (-4.50 to 5.30 mmHg) and for the FTco2 they were - 0.96 mmHg (- 7.85 to 5.92 mmHg). For the Fastrac group at an electrode temperature of 43.0°C the mean difference and limits of agreement were -1.00 mmHg and -4.58 mmHg to 2.58 mmHg. The average sensitivity and specificity for both machines for the detection of hypocarbia were 82% and 92% respectively while for hypercarbia they were 90% and 94% respectively. For hypoxaemia, the sensitivity and specificity were 40% and 94% while for hyperoxaemia the sensitivity and specificity were 83% and 97%. We conclude that both machines provide a useful supplement to arterial Pco2 measurements and the Fastrac performs better at 43.0°C. The measurement of Po2 is less accurate but is still of clinical use.

Publisher

SAGE Publications

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

Cited by 25 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Oxygen-Sensing Paint-On Bandage;Plastic and Reconstructive Surgery;2017-07

2. Monitoring Oxygenation and Gas Exchange in Neonatal Intensive Care Units: Current Practice in the Netherlands;Frontiers in Pediatrics;2015-11-03

3. Evaluation of a transcutaneous blood gas monitoring system in critically ill dogs;Journal of Veterinary Emergency and Critical Care;2014-09

4. Shock;Core Knowledge in Critical Care Medicine;2014

5. AARC Clinical Practice Guideline: Transcutaneous Monitoring of Carbon Dioxide and Oxygen: 2012;Respiratory Care;2012-11-01