Hemodynamic Performance at Rest and During Exercise After Aortic Valve Replacement: Comparison of Pulmonary Autografts Versus Aortic Homografts

Author:

Laforest Isabelle1,Dumesnil Jean G.1,Briand Martin1,Cartier Paul C.1,Pibarot Philippe1

Affiliation:

1. From the Quebec Heart Institute/Laval Hospital, Laval University, Ste-Foy, Quebec, Canada.

Abstract

Background The Ross procedure and aortic homografts have both been shown to have superior hemodynamic performance after valve replacement, but there have been few comparisons. Methods Sequential Doppler echocardiograms were performed up to 5 years after aortic valve replacement in 132 patients with the Ross procedure and 111 patients with an aortic homograft (AH). Measurements included assessment of valvular regurgitation and calculations of valve effective orifice area (EOA) and mean transvalvular gradients; the same measurements were also performed at the level of the pulmonary homograft in the Ross patients as well as during maximum exercise in 20 Ross patients and 14 AH patients. Results Aortic valve hemodynamics were stable during follow-up for both procedures and values at 1 year showed larger indexed EOAs (1.77±0.45 versus 1.42±0.35 cm 2 /m 2 , P <0.001) and lower gradients (2±3 versus 4±3 mm Hg) for the Ross procedure; similar findings were also observed during exercise (1.99±0.44 versus 1.36±0.39 cm 2 /m 2 , P <0.001 and 7±3 versus 17±11 mm Hg). Prevalence and severity of aortic regurgitation were low in both groups, although 4 patients (1 Ross, 3 AH) underwent a second operation for this reason. Also, various degrees of pulmonary homograft stenosis were found in 20% of Ross patients, 4 of which underwent a second operation. Conclusion Both procedures provide continued excellent hemodynamics of the aortic valve. The Ross procedure has a slight advantage, but this is somewhat counterbalanced by the deterioration of the pulmonary homograft in up to 20% of patients. Further studies aimed at clarifying longer-term outcomes as well as preventing pulmonary homograft stenosis with the Ross operation are clearly needed.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 33 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3