Micro Fluorescent X-Ray Analyzer

Author:

Shiraiwa Toshio,Fujino Nobukatsu

Abstract

AbstractA micro fluorescent X-ray analyzer with a focusing type of spectrometer has been developed to analyze samples of small amounts such as extracted inclusions or precipitates from metals or small areas in samples from 0.1 to 2.0 mm in diameter. This instrument is expected especially to analyze powder samples of small quantity because average values from such samples can be obtained and because surface conditions of the samples scarcely affect the results compared with their effect in electron probs microanalysis. A commercial X-ray tube is combined with a device of slits limiting incident X-rays, a focusing spectrometer with a Rowland circle of 4-in. radius, and a microscope of low magnification for observing the analyzing point on the samples. The wavelength range of the spectrometer with LiF and ADP analyzing crystals is from 1.20 to 9.94 Å, and, therefore, higher elements than aluminum in atomic number can be analyzed. The authors exerted their efforts to obtain the higher X-ray intensities in order to analyze smaller areas. The X-ray intensities obtained are satisfactory, except for light elements. For example, the detected X-ray intensity of pure nickel is 1650 cps with the use of a 0.1-mm diameter specimen, and that of pure sulfur is 52 cps with the use of a 0.1-ramdiameter specimen; however, with a 1-mm-diameter specimen, the intensity of pure nickel is over 5000 cps and that of pure sulfur is 1650 cps. These correspond to the intensities from 20-mm-diameter specimens of those elements when a flat-crystal spectrometer is used. The calibration curve for quantitative analysis generally varies with the sample area under analysis, but the same curves are obtained if the sample area is larger than 1 mm in diameter. Then, powder samples are analyzed quantitatively by using a plastic sample holder of 1-mm diameter and 0.3-mm depth. This instrument has good ability for microanalyzing trace elements by, for example, the ion-exchenge membrane method. The sensitivity represented is nearly 5000 cps/μg for Ni Kα from NiSO4 that is soaked and dried in thin rice paper. Some applications of the micro fluorescent X-ray analyzer to precipitates in steels and corrosion products are reported.

Publisher

Cambridge University Press (CUP)

Reference11 articles.

1. X-Ray Fluorescence Spectroscopy in Biology and Medicine

2. Birks L. S. , “Comparison of X-Ray Fluorescence and Electron Probe Methods: Future Trends,” ASTM STP No. 349, p. 151, 1964.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3