Validation of Alternative Methods for the Analysis of Drinking Water and Their Application to Escherichia coli

Author:

Boubetra Abdelkader1,Le Nestour François1,Allaert Corrie2,Feinberg Max3

Affiliation:

1. Institut Scientifique d'Hygiène et d'Analyse (ISHA), 25 Ave. de la République, 91300 Massy, France

2. IDEXX Laboratories, c/ Plom, no. 2-8, 3°, 08038 Barcelona, Spain

3. Institut National de la Recherche Agronomique, Met@risk, 16 Rue Claude Bernard, F-75231 Paris Cedex 05, France

Abstract

ABSTRACT In Europe, the Drinking Water Directive of the European Commission indicates which methods (most of which are CEN/ISO-standardized methods) should be used for the analysis of microbiological parameters (European Commission, Environment, Council Directive 98/83/EC of 3 November 1998). According to the Directive, alternative methods “may be used, providing it can be demonstrated that the results obtained are at least as reliable as those produced by the methods specified.” The prerequisite for the routine use of any alternative method is to provide evidence that this method performs equivalently to the corresponding reference method. In this respect, the ISO 16140 standard (ISO, ISO 16140. Microbiology of Food and Animal Feeding Stuffs—Protocol for the Validation of Alternative Methods , 2003) represents a key issue in generating such a procedure based on an interlaboratory study. A new statistical tool, called the accuracy profile, has been developed to better interpret the data. The study presented here is based upon the enumeration of Escherichia coli bacteria in water. The reference method may require up to 72 h to provide a confirmed result. The aim of this publication is to present data for an alternative method by which results can be obtained in 18 h (Colilert-18/Quanti-Tray) based upon defined substrate technology (DST). The accuracy profile is a statistical and graphical decision-making tool and consists of simultaneously combining, in a single graphic, β expectation tolerance intervals (β-ETIs) and acceptability limits (λ). The study presents the validation criteria calculated at the three levels of contamination used in the trial for a β equal to 80% and a λ equal to ±0.3 and combines the accuracy profiles of Escherichia coli for a λ of ±0.3 log 10 unit/100 ml, a λ of ±0.4 log 10 unit/100 ml, and a β of 80% or 90%. Several interesting conclusions can be drawn from these data. The accuracy profile method has been applied to the validation of the Colilert-18/Quanti-Tray method against reference method ISO 9308-1 (ISO, ISO 9308 - 1. Water Quality—Detection and Enumeration of Escherichia coli and Coliform Bacteria. Part 1. Membrane Filtration Method , 2000), using a β of 80% and a λ of 0.4; the alternative method can be validated between 1.00 and 2.05 log 10 units/100 ml, equivalent to 10 to 112 CFU/100 ml.

Publisher

American Society for Microbiology

Subject

Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology

Reference22 articles.

1. Anonymous. 2002. AFAQ AFNOR certification. Exigences relatives aux études préliminaire et collaborative menées par un laboratoire expert. Internal report revision 7. AFAQ AFNOR Saint-Denis France.

2. Lessons from the organization of a proficiency testing program in food microbiology by interlaboratory comparison: analytical methods in use, impact of methods on bacterial counts and measurement uncertainty of bacterial counts;Augustin J. C.;Food Microbiol.,2006

3. Commission of the European Communities. 2005. Commission regulation (EC) no. 2073/2005 of 15 November 2005 on microbiological criteria for foodstuffs. European Commission Brussels Belgium. http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2005:338:0001:0026:EN:PDF.

4. A critical review of measurement uncertainty in the enumeration of food micro-organisms;Corry J. E. L.;Food Microbiol.,2007

5. Comparison of Membrane Filtration and Multiple-Tube Fermentation by the Colilert and Enterolert Methods for Detection of Waterborne Coliform Bacteria, Escherichia coli , and Enterococci Used in Drinking and Bathing Water Quality Monitoring in Southern Sweden