Microbiological Studies on the Performance of a Laminar Airflow Biological Cabinet

Author:

Mcdade Joseph J.12,Sabel Fred L.12,Akers Ronald L.12,Walker Robert J.12

Affiliation:

1. Biohazards Department, Pitman-Moore Division, The Dow Chemical Company, Zionsville, Indiana 46077

2. Engineering Department, Behrent Engineering Company, Denver, Colorado 80211

Abstract

Engineering and microbiological tests indicated that a typical, commercial laminar airflow cabinet was not effective in providing either product protection or agent containment. The cabinet was modified and tested through a series of alternate configurations to establish a set of design criteria. A mock-up cabinet was developed from these design criteria. The mock-up unit was evaluated for efficiency in providing both product protection and agent containment. In these evaluations, challenge methods were developed to simulate normal, in-use laboratory operations. Controlled bacterial or viral aerosol challenges were used at higher than normal levels to provide stringent test conditions. Test results indicated that the mock-up unit was considerably better in preventing agent penetration (0.1 to 0.2 particles per 100 ft 3 of air) than the commercial cabinet (5 to 6 particles per 100 ft 3 of air) during product protection tests. Similarly, agent containment was considerably better in the new cabinet (particle escape of 2 to 3 per 100 ft 3 of air at only one of the five test sites) than in the commercial cabinet (particle escape of 2 to 14 per 100 ft 3 of air at three of the five test sites).

Publisher

American Society for Microbiology

Subject

General Pharmacology, Toxicology and Pharmaceutics,General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

Reference16 articles.

1. Methods of study of bacterial viruses;Adams M. H.;Methods Med. Res.,1950

2. Barbeito M. S. 1965. Biological safety evaluation of a commercial vaccine production laboratory. U.S. Army Biol. Labs. Ft. Detrick Frederick Md. Tech. Rept. No. 65.

3. Dow Biohazards Department. 1967. Evaluation of safety cabinets and test laboratory. The Dow Chemical Co. Pitman-Moore Div. Tech. Rept. No. BH 67-01-014.

4. Comparative levels and types of microbial contamination detected in industrial clean rooms;Favero M. S.;Appl. Microbiol.,1966

5. Use of laminar air-flow equipment in microbiology;Favero M. S.;Appl. Microbiol.,1968

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献