Affiliation:
1. Microbiology Laboratories, Veterinary Department, Chow Research Division, Ralston Purina Company, St. Louis, Missouri 63199
Abstract
Comparative studies of fluorescent antibody procedure and a cultural method for the detection of
Salmonella
were made on 1,013 feed and feed-ingredient samples. The agreement between the two methods was 92.1%. There were more false positives (5.7%) than false negatives (2.2%). Of the 22 false negatives, 15 (68%) were obtained on meat meal. Of the total number of samples, 37% were meat meal. An additional study of 73 samples of meat meal indicated that correlation between methods was better than correlation between samples.
Publisher
American Society for Microbiology
Subject
General Pharmacology, Toxicology and Pharmaceutics,General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine
Cited by
6 articles.
订阅此论文施引文献