Dopant profiling of ion-implanted GaAs by terahertz time-domain spectroscopy

Author:

Sahoo Anup Kumar1ORCID,Au Wei-Chen1ORCID,Hong Yu-Cheng2ORCID,Pan Ci-Ling12ORCID,Zhai Dongwei34ORCID,Hérault Emilie3ORCID,Garet Frédéric3ORCID,Coutaz Jean-Louis3ORCID

Affiliation:

1. Department of Physics, National Tsing Hua University 1 , Hsinchu City 30013, Taiwan

2. Institute of Photonics Technologies, National Tsing Hua University 2 , Hsinchu City 30013, Taiwan

3. IMEP-LAHC, Université Savoie Mont Blanc 3 , 73 376 Le Bourget du Lac Cedex, France

4. 4College of Physics, Qingdao University, Qingdao 266071, China

Abstract

We investigate terahertz time-domain spectroscopy (THz-TDS) as a non-destructive and non-contact technique for depth profiling of dopants in semiconductors. THz temporal waveforms transmitted through silicon-ion-implanted semi-insulating gallium arsenide substrates, as-implanted or post-annealed by rapid thermal annealing, were analyzed by assuming a multi-layered Gaussian refractive index profile in the ∼sub-micrometer-thick implantation region. The implantation energy and dosages in this work were 200 KeV, 1014, 5 × 1014, and 1015 ions/cm2, respectively. The average values of real (n) and imaginary (κ) parts of refractive indices of an as-implanted sample in the depth range of 0–800 nm are 5.8 and 0.7, respectively, at 0.5 THz and are 6.2 and 0.2, respectively, at 1 THz. On the other hand, the refractive index profile of the post-annealed samples displays a prominent Gaussian-like form, and peak refractive indices (n ∼ 25 and κ ∼ 32.7 at 0.5 THz and n, κ ∼17 at 1 THz) were found to be at the depth of 210 nm. Reconstructed dopant profiles in as-implanted, implanted, and post-annealed substrates were found to be in good agreement with measurements by secondary ion mass spectroscopy as well as simulation by the Monte Carlo method. We were also able to determine accurately the projected range (Rp), straggle (Rs), and concentration of dopants by the analysis of THz-TDS data. The spatial resolution, along the depth direction, of the THz-TDS technique for depth profiling of dopants was estimated to be as small as 8-nm. This work suggests the feasibility of using THz-TDS for nondestructive and non-contact diagnostics for profiling dopants in semiconductors.

Funder

Ministry of Science and Technology, Taiwan

Agence Nationale de la Recherche

Publisher

AIP Publishing

Subject

General Physics and Astronomy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3