Lysis Timer: a new sensitive tool to diagnose hyperfibrinolysis in liver transplantation

Author:

Roullet StéphanieORCID,Labrouche Sylvie,Mouton Christine,Quinart Alice,Nouette-Gaulain Karine,Laurent Christophe,Freyburger Geneviève

Abstract

AimsDiagnosis of hyperfibrinolysis in orthotopic liver transplantation (OLT) remains challenging. Euglobulin clot lysis time (ECLT) is not adapted to clinical situations. ROTEM is specific but seldom sensitive to hyperfibrinolysis. The Lysis Timer assesses ‘Global Fibrinolytic Capacity’ in citrated plasma (GFC/LT). GFC/LT associates reagents for in vitro triggering of the clot (thrombin and calcium) and its lysis (tissue-plasminogenactivator (t-PA)), turbidity signal acquisition by the Lysis Timer, and dedicated software converting the digital signal into an optical curve. A visual check of the curves was systematic to ascertain the lysis time values calculated by the software. The primary aim of this prospective observational study was to evaluate the ability of GFC/LT to recognise hyperfibrinolysis during OLT. The secondary aim was to compare its results with ROTEM maximum lysis (EXTEM ML) and with standard laboratory tests.MethodsThirty consecutive adult patients undergoing OLT were included (NCT03012633). Standard laboratory tests, ROTEM, GFC/LT, ECLT and fibrinolysis parameters were assayed at five sample times.ResultsGFC/LT was correlated with ECLT, plasmin activator inhibitor 1 antigen and activity and t-PA activity (r=0.490, 0.681, 0.643 and –0.359, respectively). Hyperfibrinolysis was defined as ECLT ≤60 min. Receiver operating characteristic curve analysis showed that GFC/LT with a threshold of 31 min detected hyperfibrinolysis with a sensitivity of 0.88 (95% CI 0.73 to 0.96), a specificity of 0.68 (95% CI 0.56 to 0.78) and an area under the curve (AUC) of 0.85 (95% CI 0.74 to 0.94). EXTEM ML >12% did not detect hyperfibrinolysis (sensitivity 0.38 (95% CI 0.24 to 0.55), specificity 0.95 (95% CI 0.86 to 0.99) and AUC 0.60 (95% CI 0.46 to 0.75)).ConclusionsGFC/LT recognised hyperfibrinolysis during OLT with a significant agreement with the other tests of fibrinolysis.Trial registration numberNCT03012633.

Publisher

BMJ

Subject

General Medicine,Pathology and Forensic Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3