Sonorheometry Device Thresholds in Liver Transplantation: An Observational Retrospective Study

Author:

Soucy-Proulx Maxim12,Kato Hiromi1ORCID,Coeckelenbergh Sean13,Naili Kortaia Salima1,Herboulier Laurence1,Pittau Gabriella4,Pham Patrick5,Lemoine Antoinette5,Duranteau Jacques6,Roullet Stéphanie17ORCID

Affiliation:

1. Service d’Anesthésie-Réanimation, Hôpital Paul Brousse, Assistance Publique—Hôpitaux de Paris (AP-HP), Université Paris Saclay, 94800 Villejuif, France

2. Department of Anesthesiology, Centre Hospitalier de l’Université de Montréal, Montreal, QC H2X 0A9, Canada

3. Outcomes Research Consortium, Cleveland, OH 44195, USA

4. Centre Hépato-Biliaire, Hôpital Paul Brousse, Assistance Publique—Hôpitaux de Paris (AP-HP), Université Paris Saclay, 94800 Villejuif, France

5. Service de Biochimie et Oncogénétique, Hôpital Paul Brousse, Assistance Publique—Hôpitaux de Paris (AP-HP), Université Paris Saclay, 94800 Villejuif, France

6. Department of Anesthesiology and Intensive Care, Bicêtre Hospital, Assistance Publique Hôpitaux de Paris (AP-HP), Université Paris Saclay, 94276 Le Kremlin-Bicêtre, France

7. INSERM, Hémostase Inflammation Thrombose HITH U1176, Université Paris Saclay, 94276 Le Kremlin-Bicêtre, France

Abstract

Background: Liver transplantation (LT) remains a potentially haemorrhagic procedure whose perioperative bleeding and transfusion could be better monitored using point-of-care devices. Quantra® is a device based on sonorheometry to assess whole blood clot formation. Our aims were to describe Quantra® parameters during LT and to study their correlations with standard laboratory parameters, and to determine Quantra® cut-off values for thrombocytopenia, hypofibrinogenemia and coagulation factors’ deficit. Methods: In 34 patients undergoing LT, blood samples were collected before surgical incision, 15 min after the beginning of the anhepatic phase, and 15 min after arterial revascularization of the graft. Results: Clotting time (CT) was well correlated with prothrombin (PT) ratio and activated partial thromboplastin time (aPTT) ratio. Platelet contribution to clot stiffness (PCS) was correlated with platelets (ρ = 0.82, p < 0.001) and fibrinogen contribution clot stiffness (FCS) with fibrinogen (Fg) (ρ = 0.74, p < 0.001). CT predicted a PT ratio < 30% with an area under the curve (AUC) of 0.93 (95% CI 0.87–0.98; p < 0.001). PCS predicted a platelet count < 50 G/L with an AUC of 0.87 (95% CI 0.76–0.98, p < 0.001). FCS predicted a Fg < 1.0, 1.2 or 1.5 g/L, with an AUC of 0.86 (95% CI 0.77–094, p < 0.001), 0.82 (95% CI 0.74–0.91, p < 0.001) and 0.88 (95% CI 0.82–0.95, p < 0.001), respectively. Conclusion: Quantra® provides a rapid assessment of haemostasis during LT.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3