Author:
Tsai Wen-Chi,Chen Po-Quang,Lu Tung-Wu,Wu Shing-Sheng,Shih Kao-Shang,Lin Shang-Chih
Abstract
Abstract
Background
This study was designed to derive the theoretical formulae to predict the pullout strength of pedicle screws with an inconstant outer and/or inner diameter distribution (conical screws). For the transpedicular fixation, one of the failure modes is the screw loosening from the vertebral bone. Hence, various kinds of pedicle screws have been evaluated to measure the pullout strength using synthetic and cadaveric bone as specimens. In the literature, the Chapman's formula has been widely proposed to predict the pullout strength of screws with constant outer and inner diameters (cylindrical screws).
Methods
This study formulated the pullout strength of the conical and cylindrical screws as the functions of material, screw, and surgery factors. The predicted pullout strength of each screw was compared to the experimentally measured data. Synthetic bones were used to standardize the material properties of the specimen and provide observation of the loosening mechanism of the bone/screw construct.
Results
The predicted data from the new formulae were better correlated with the mean pullout strength of both the cylindrical and conical screws within an average error of 5.0% and R
2 = 0.93. On the other hand, the average error and R
2 value of the literature formula were as high as -32.3% and -0.26, respectively.
Conclusion
The pullout strength of the pedicle screws was the functions of bone strength, screw design, and pilot hole. The close correlation between the measured and predicted pullout strength validated the value of the new formulae, so as avoid repeating experimental tests.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Rheumatology
Reference28 articles.
1. Zdero R, Rose S, Schemitsch EH, Papini M: Cortical screw pullout strength and effective shear stress in synthetic third generation composite femurs. J Biomech Eng. 2007, 129: 289-293. 10.1115/1.2540926.
2. Ansell RH, Scales JT: A study of some factors which affect the strength of screws and their insertion and holding power in bone. J Biomech. 1986, 1: 279-302. 10.1016/0021-9290(68)90023-7.
3. Asnis SE, Ernberg JJ, Bostrom MP, Wright TM, Harrington RM, Tencer AF, Peterson M: Cancellous bone screw thread design and holding power. J Orthop Trauma. 1996, 10: 462-469. 10.1097/00005131-199610000-00003.
4. Chapman JR, Harrington RM, Lee KM, Anderson PA, Tencer AF, Kowalski D: Factors affecting the pullout strength of cancellous bone screws. J Biomech Eng. 1996, 118: 391-398. 10.1115/1.2796022.
5. Steeves M, Stone C, Mogaard J, Byrne S: How pilot-hole size affects bone-screw pullout strength in human cadaveric cancellous bone. Canad J Surg. 2005, 48 (3): 207-212.
Cited by
49 articles.